Use of a Minimally Invasive Cardiac Output Monitor to Optimise Haemodynamics in a Patient with Mitral Valve Disease Undergoing Cerebrovascular Surgery

Journal Title: Sultan Qaboos University Medical Journal - Year 2017, Vol 17, Issue 3

Abstract

Patients with mitral valve disease undergoing cerebrovascular surgery face increased inherent risks due to their associated cardiac comorbidities. As such, the anaesthetic management of such patients is distinctly challenging. Simultaneous consideration of both the cerebrovascular and underlying cardiac conditions determines key anaesthetic issues, as fluids and vasopressors or inotropes need to be titrated according to haemodynamic variables in order to optimise cerebral blood flow without compromising cardiac function. We report a 45-yearold female patient with mild mitral stenosis and moderate-to-severe mitral regurgitation who presented to the Khoula Hospital, Muscat, Oman, in 2016 following a ruptured anterior communicating artery aneurysm requiring urgent surgical intervention. As highlighted in this case, the VolumeView EV1000™ (Edwards Lifesciences, Irvine, California, USA) system is a minimially invasive haemodynamic monitor that can help immensely in the perioperative management of such patients.

Authors and Affiliations

Ali M. Al-Mashani| Departments of Neurosurgery, Intensive Care Unit & Pain Management, Khoula Hospital, Muscat, Oman, Niranjan D. Waje| Department of Cardiac Anaesthesia, Royal Hospital, Muscat, Oman, Neeraj Salhotra| Departments of Neurosurgery, Intensive Care Unit & Pain Management, Khoula Hospital, Muscat, Oman, Samaresh Das| Departments of Anaesthesia, Intensive Care Unit & Pain Management, Khoula Hospital, Muscat, Oman, Neelam Suri| Departments of Anaesthesia, Intensive Care Unit & Pain Management, Khoula Hospital, Muscat, Oman, Rashid A. Al-Sheheimi| Anaesthesia Residency Programme, Oman Medical Speciality Board, Muscat, Oman, Nilay Chatterjee| Departments of Anaesthesia, Intensive Care Unit & Pain Management, Khoula Hospital, Muscat, Oman

Keywords

Related Articles

Successful Resuscitation of an Extremely Low Birth Weight Premature Infant in Delma Island Community Hospital, United Arab Emirates

Because of their physical size and physiological immaturity, resuscitation of extremely very low birth weight premature infants is a big dilemma for neonatologists in any hospital. Te resuscitation may present an addit...

Effectiveness and Needs Assessment of Faculty Development Programme for Medical Education: Experience from Saudi Arabia

Objectives: Faculty members are the most important resource in any institution of higher education as medical education has been, and continues to be, a priority for medical colleges in Saudi Arabia. This study aimed to...

National Prevalence of Micronutrient Deficiencies, Anaemia, Genetic Blood Disorders and Over- and Undernutrition in Omani Women of Reproductive Age and Preschool Children

A national cross-sectional survey was conducted to estimate the prevalence of anaemia, micronutrient deficiencies, haemoglobin disorders and over- and undernutrition in children and women of reproductive age in Oman. Was...

Download PDF file
  • EP ID EP14801
  • DOI 10.18295/squmj.2017.17.03.015
  • Views 309
  • Downloads 22

How To Cite

Ali M. Al-Mashani, Niranjan D. Waje, Neeraj Salhotra, Samaresh Das, Neelam Suri, Rashid A. Al-Sheheimi, Nilay Chatterjee (2017). Use of a Minimally Invasive Cardiac Output Monitor to Optimise Haemodynamics in a Patient with Mitral Valve Disease Undergoing Cerebrovascular Surgery. Sultan Qaboos University Medical Journal, 17(3), 343-347. https://europub.co.uk/articles/-A-14801