Sonographic Optic Nerve Sheath Diameter as a Screening Tool for Detection of Elevated Intracranial Pressure

Journal Title: Archives of Academic Emergency Medicine - Year 2013, Vol 1, Issue 1

Abstract

Introduction: Timely diagnosis and treatment of post-traumatic elevated intracranial pressure (EICP) could be re-duced morbidity and mortality, and improved patients’ outcome. This study is trying to evaluate the diagnostic accu-racy of sonographic optic nerve sheath diameter (ONSD) in detection of EICP. Methods: Sonographic ONSD of pa-tients with head trauma or cerebrovascular accident suspicious for EICP were evaluated by a trained chief resident of emergency medicine, who was blind to the clinical and brain computed tomography scan (BCT) findings of patients. Immediately after ultrasonography, BCT was performed and reported by an expert radiologist without awareness from other results of the patients. Finally, ultrasonographic and BCT findings regarding EICP were compared. To evaluate the ability of sonographic ONSD in predicting the BCT findings and obtain best cut-off level, receiver operat-ing characteristic (ROC) curve were used. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of sonographic ONSD in determin-ing of EICP was calculated. P < 0.05 was considered as statistically significant. Results: There were 222 patients (65.3% male), with mean age of 42.2±19.5 years (range: 16-90 years). BCT showed signs of EICP, in 28 cases (12.6%). The means of the ONSD in the patients with EICP and normal ICP were 5.5 ± 0.56 and 3.93 ± 0.53 mm, re-spectively (P<0.0001). ROC curve demonstrated that the best cut off was 4.85 mm. Sensitivity, specificity, PPV, NPV, PLR, and NLR of ONSD for prediction of EICP were 96.4%, 95.3%, 72.2%, 98.9%, 20.6, and 0.04, respectively. Con-clusion: Sonographic diameter of optic nerve sheath could be considered as an available, accurate, and noninvasive screening tool in determining the elevated intracranial pressure in cases with head trauma or cerebrovascular acci-dent.

Authors and Affiliations

Keywords

Related Articles

Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study

Introduction: Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availabilit...

Urgent Need to Strengthen the Chain of Survival in the United Arab Emirates; a Letter to the Editor

Further to our recently published findings, we have completed the analysis of our second year of prehospital data collection for the same service (1). We wish to expedite the availability of this data to clinicians, rese...

The Accuracy of Plain Radiography in Detection of Traumatic Intrathoracic Injuries

Introduction: Rapid diagnosis of traumatic intrathoracic injuries leads to improvement in patient management. This study was designed to evaluate the diagnostic value of chest radiography (CXR) in comparison to chest com...

Urinary Retention and Air in the Spinal Canal; a Case Report

Cauda equina syndrome (CES) although uncommon, is a very serious condition, which should be diagnosed as soon as possible. Urinary dysfunction following a lumbosacral trauma is a key for the physician to consider CES as...

Vagus Nerve Stimulation and External Defibrillation during Resuscitation; a Letter to Editor

External defibrillation in patients with implanted neuromodulatory devices is a crucial therapeutic challenge. We report a 63-year-old male patient with refractory epilepsy (RE) after recurrent ischaemic strokes in the m...

Download PDF file
  • EP ID EP318646
  • DOI -
  • Views 232
  • Downloads 0

How To Cite

(2013). Sonographic Optic Nerve Sheath Diameter as a Screening Tool for Detection of Elevated Intracranial Pressure. Archives of Academic Emergency Medicine, 1(1), 15-19. https://europub.co.uk/articles/-A-318646