Evaluation of Myocardial Perfusion Imaging SPECT Parameters and Pharmacologic Stress Test with Adenosine Versus Coronary Angiography Findings: Are They Diagnostically Concordant?

Journal Title: Molecular Imaging and Radionuclide Therapy - Year 2018, Vol 28, Issue 2

Abstract

Objectives: In this study our first aim was to evaluate the diagnostic concordance of myocardial perfusion scintigraphy (MPS) by pharmacological stress test with adenosine (APST) with coronary angiography (CAG). The secondary aim of this study was to evaluate the correlation between CAG findings and automated analysis parameters such as left ventricular ejection fraction, summed stress score (SSS), summed rest score, summed difference score (SDS), stress MPS defect percentage ratio (extent) and transient ischemic dilation (TID) obtained by myocardial perfusion imaging single-photon emission computed tomography (SPECT). Methods: A total of 129 patients (62 male, 67 female, median age: 60.02) undergoing MPS due to suspicion of coronary ischemia who also underwent subsequent CAG in the last year were included in this study, their MPS data and CAG results were compared. Results: There was no statistically significant diagnostic concordance when visual evaluation of MPS, quantitative MPS parameters and exercise treadmill test (ETT) electrocardiography results were used alone. In fact, diagnostic concordance was higher when automated analysis parameters like TID, SSS and extent values were added to MPS SPECT visual analyses. There was diagnostic concordance in 57.9% of APST patients and 41.7% of ETT patients. There was diagnostic concordance in 75.8% of APST patients and 52.6% of ETT patients who were older than 65 years of age. Conclusion: In our study, we found that the use of APST during MPS increases diagnostic concordance with CAG. Therefore, we think that it would be appropriate to use APST in women and elderly patients with limited exercise habits. The CAG diagnostic mismatch is far above what it should be when MPS reporting is only done with visual data, and it is not supported by quantitative data such as TID, SSS, SDS and extent.

Authors and Affiliations

Zekiye Hasbek, Seyit Ahmet Ertürk, Ali Çakmakçılar, İbrahim Gül, Ahmet Yılmaz

Keywords

Related Articles

Metabolic Characteristics and Diagnostic Contribution of 18F-FDG PET/CT in Gastric Carcinomas

Objectives: The aim of this study was to evaluate 18F-fluoro-2-deoxy-glucose (FDG) uptake patterns in primary tumors and metastatic lesions, and also to assess the diagnostic contribution of positron emission tomography/...

Minimal Invasive Radioguided Ectopic Parathyroidectomy in Upper Mediastinum

In this study we wanted to present a case with the history of multiple previous neck explorations and persisting upper mediastinal ectopic parathyroid adenoma who underwent a successful operation with radioguided minimal...

Red Marrow Absorbed Dose Calculation in Thyroid Cancer Patient Using a Simplified Excel Spreadsheet

Objectives: Absorbed dose to red marrow (Drm) can be calculated using blood dosimetry. However, this method is laborious and invasive. Therefore, image-based dosimetry is the method of choice. Nonetheless, the commercial...

Four Atypical Parathyroid Adenomas Detected by Dual Phase Tc-99m MIBI SPECT

We report a case of a 55-year-old female with tertiary hyperparathyroidism and osteoporosis who had end stage renal disease and a history of hemodialysis for 15 years. Patient’s informed is taken. Neck ultrasonography sh...

Download PDF file
  • EP ID EP48964
  • DOI 10.4274/mirt.2019.47450
  • Views 217
  • Downloads 0

How To Cite

Zekiye Hasbek, Seyit Ahmet Ertürk, Ali Çakmakçılar, İbrahim Gül, Ahmet Yılmaz (2018). Evaluation of Myocardial Perfusion Imaging SPECT Parameters and Pharmacologic Stress Test with Adenosine Versus Coronary Angiography Findings: Are They Diagnostically Concordant?. Molecular Imaging and Radionuclide Therapy, 28(2), -. https://europub.co.uk/articles/-A-48964