COMPARISON OF NUMBER OF DIFFUSION GRADIENT DIRECTION IN BRAIN IMAGING DIFFUSION TENSOR; CASE STUDY OF TUMOR BRAIN

Journal Title: Journal of Vocational Health Studies - Year 2017, Vol 1, Issue 1

Abstract

Background : Diffusion Tensor Imaging (DTI), namely MRI sequence which is the diffusion of water analysis that shows the complex structure of brain tissue. The weakness of this sequence is scanning time. Number of Diffusion Gradient Direction (NDGD) is one of parameter that effect scanning time. Purpose: This study has aim to compare between NDGD 25 and NDGD 15 in brain tumor. Methods: This study used observational analytic study with prospective approach. Five patients were examined using DTI sequence with NDGD 25 and NDGD 15. The parameter for evaluating the quality image is of Fractional Anisotropy (FA) and Fiber Tracking (FT). Result: Image with NDGD 25 was better than NDGD 15, but the difference was not significantly. Conclusion: It can be concluded that NDGD 15 can be solution to get informative image with short scan time when DTI sequence is used to examine brain tumor.

Authors and Affiliations

Afif Rofiky, Paulus Rahardjo, Didik Soeharmanto

Keywords

Related Articles

ANALYSIS OF FRACTIONAL ANISOTROPY (FA) VALUES AND APPARENT DIFFUSION COEFFICIENT (ADC) VALUES IN ISCHEMIC STROKE DISEASES OF MRI GE 3 TESLA

Background: Diffusion Weighted Imaging and Diffusion Tensor Imaging is an advanced technique in MRI that shows the diffusion in brain of ischemic stroke disease. Diffusion Weighted Imaging (DWI) shows the lesions without...

THE RADIATION DOSE PROFILE IN PEDIATRIC INTERVENTIONAL CARDIOLOGY TO ESTIMATE THE STOCHASTIC EFFECT RISK: PRELIMINARY STUDY

Background: The specific characteristic of anatomy and physiology of children cause the risk of radiation effects received when they underwent the interventional cardiology procedures higher than an adult. Purpose: to es...

PATTERN OF DEMAND FOR MAKING DENTURES AT DENTAL LABORATORY IN SURABAYA CITY, INDONESIA

Background: Dental laboratory in Surabaya frequently make various kinds of the denture. But surely there is a case that was the most commonly accepted, to adjust to the needs of dental laboratories on the priorities of t...

RISK ASSESSMENT OF OVERHEAD CRANE (OHC) DOUBLE GIRDER OPERATION IN THE KAPAL NIAGA DIVISION IN PT PAL INDONESIA (PERSERO)

Background: PT PAL Indonesia (Persero) operates Overhead Crane Double Girder tool everyday. The operation of the device have some risk of material hazard, material pinched, material scratched, fracture and passed away. P...

HAZARDS IDENTIFICATION AND RISK ASSESSMENT OF PHYSICAL AND MECHANICAL FACTORS OF FORKLIFT OPERATIONAL IN PT SINAR INDOGREEN KENCANA AAC PRODUCTION AREA’S

Background: Forklift is one of the most used craning plane in the manufacture and logistics industry. The operational of forklift can cause fatality work accident. PT SIGK uses forklift in the daily production activities...

Download PDF file
  • EP ID EP594024
  • DOI 10.20473/jvhs.V1.I1.2017.15-17
  • Views 363
  • Downloads 0

How To Cite

Afif Rofiky, Paulus Rahardjo, Didik Soeharmanto (2017). COMPARISON OF NUMBER OF DIFFUSION GRADIENT DIRECTION IN BRAIN IMAGING DIFFUSION TENSOR; CASE STUDY OF TUMOR BRAIN. Journal of Vocational Health Studies, 1(1), 15-17. https://europub.co.uk/articles/-A-594024