On the Equivalent Sources and Geometric Factor Calculation for a Circular Detection Case

Abstract

In all absolute measurements of the intensity of the radioactive materials and calibration of the detectors, it is essential the knowledge of the geometric efficiency. This work describes how to obtain the sources with different geometries and equal geometric efficiency (equivalent sources for geometric factor), corresponding to a linear, circumferential and circular homogeneous sources parallel to a circular detector. It is estimated the geometric factor of them by the Monte Carlo method. The results are compared with the published in the literature, thus confirming the validity of this method.

Authors and Affiliations

A. Tony Viloria, Luis Montiel, Laszlo Sajo-Bohus, Daniel Palacios

Keywords

Related Articles

Shape Coexistence in Hot Rotating 100Nb

Temperature and angular momentum induced shape changes in the well deformed 100Nb have been investigated within the theoretical framework of Statistical theory combined with triaxially deformed Nilson potential and Strut...

An application of PIXE technique to Proto Crustal Rocks: Geo chemical evaluation of Granulitic Charnockites of Eastern Ghats, Andhrapradesh, India

In this work, PIXE has been used for a variety of Precambrian proto crustal rocks in the form of granulitic charnockites,Eastern Ghats AP,India. In previous study of exterior part of the charnockite hill elemental analys...

Gamma Radiation Doses Effects on Mechanical Properties and Microwave Absorption Capacity of Rubber Doped Concrete

The main raw material for the construction industry is concrete; whose fundamental components are the fine and coarse aggregates, water and cement. For the obtaining of these materials are necessary activities that gener...

Nucleosynthesis in Neutron Stars Crust

We address the problem of the origin of heavier and super heavy elements in nature. Believing rapid neutron capture process (r-process) is responsible for synthesis of heavy and super heavy elements in the remnants of su...

Proposal of a Novel Setup for Linac Monitoring Using a Specifically Designed Plastic Scintillator and a Spectrophotometer

In this work, we report the design, implementation, and results of an alternative monitoring system for a linear accelerator (LINAC) used in medical therapy. The system proposed consist in as lab of scintillator plastic...

Download PDF file
  • EP ID EP595471
  • DOI 10.15415/jnp.2016.41004
  • Views 221
  • Downloads 0

How To Cite

A. Tony Viloria, Luis Montiel, Laszlo Sajo-Bohus, Daniel Palacios (2016). On the Equivalent Sources and Geometric Factor Calculation for a Circular Detection Case. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 4(1), 31-48. https://europub.co.uk/articles/-A-595471