AKURASI HITUNG JUMLAH ERITROSIT METODE MANUAL DAN METODE OTOMATIS

Journal Title: Medical Laboratory Technology Journal - Year 2017, Vol 3, Issue 2

Abstract

In a laboratory, an erythrocyte is done by using hemocytometer and microscope. The task is to measure and assess the size and shape of the erythrocyte. But this procedure is time consuming, complex and tedious. As a solution to this problem, to provide an automated, cost-effective and efficient alternative to detection and counting of erythrocyte, hematology analyzers are used. However, false results related either to erythrocyte or other parameters from complete blood count may be observed in several instances. The objective study was to compare the accuracy of erythrocyte count results of automatic hematological analysis by the manual method. The study is an analytic survey with a cross-sectional design. Erythrocyte counting is done by using three types of control blood, namely high, normal and low, with 9 repetitions. In high control blood, the mean erythrocytes count by the manual method was 7.08 million/μl with a bias value of 1.4%, while that by the automated method was 7.03 million/μl with a bias value of 0.7%. The mean erythrocyte count in normal control blood by the manual method was 4.50 million/μl with a bias value of 0.9%, while that by the automated method was 4.4 million/μl with a bias value of 2.4%. And in low control blood, the mean erythrocyte count by the manual method was 1.72 million/μl with 4.4% bias value, while that the automated method was 1.67 million/μl with 1.2% bias value. Statistical analysis showed no significant difference in accuracy between the erythrocyte count of manual methods with automated methods.

Authors and Affiliations

Keywords

Related Articles

KADAR LOGAM TIMBAL (Pb) DALAM DARAH PENJUAL KLEPON

A kelepon seller is one of the groups susceptible to metal pollution from motor vehicle emissions from the tetraethyl-Pb and tetramethyl-Pb combustion products that are always added to motor vehicle fuel. Lead metal has...

AYA HAMBAT NaCl TERHADAP PERTUMBUHAN Staphylococcus aureus

Staphylococcus aureus is a pathogenic bacterial that causes infectious disease and human poisoning through enterotoxin produced by the bacteria. Salt or sodium chloride is used by human for food preservation process beca...

SERUM LIPEMIK DENGAN FLOKULAN GAMMA-SIKLODEKSTRIN PADA PEMERIKSAAN GLUKOSA

Lipemic serum caused by lipoprotein particles such as chylomicrons, VLDL (Very Low-Density Lipoprotein) and triglycerides. This situation causes interference chromophoric photometric analysis, interference on the wavelen...

PENGARUH SIMPLISIA BUNGA KENANGA (CANANGA ODORATA (LAMK). HOOK.) SEBAGAI MAT ELEKTRIK TERHADAP KNOCK-DOWN NYAMUK AEDES AEGYPTI

The main vector of dengue fever is Aedes aegypti. Ylang flower can be useful as an anti-mosquito, so in this study ylang flower botanicals chosen as rechargeable electric mat as an anti-mosquito Aedes aegypti. Objectives...

LIME SOAP AS BACTERIA REDUCER

Some people in South Kalimantan have used river water to fulfill their daily needs include washing the utensils. Wash the cutlery use river water can cause disease transmission. Squeezed lime has an antibacterial effect...

Download PDF file
  • EP ID EP414977
  • DOI -
  • Views 129
  • Downloads 0

How To Cite

(2017). AKURASI HITUNG JUMLAH ERITROSIT METODE MANUAL DAN METODE OTOMATIS. Medical Laboratory Technology Journal, 3(2), -. https://europub.co.uk/articles/-A-414977