Annihilation of Dipolar Dark Matter: χχ→γγ

Abstract

In this work we study the annihilation of dark matter, considering it as a neutral particle with magnetic and/or electric moments not null. The calculation of the effective section of the process χχbar→γγ → is made starting from a general form of coupling χχbar γ in the framework of an extension of the Standard Model. We found, when taking into account an annihilation of DDM-antiDDM to monoenergetic photons, that for small masses, mχ ≤ 0 GeV, an electric dipole moment ~10–6 e cm is required to satisfy the current residual density, while for the range of greater sensitivity of HAWC, 10 TeV < Eg < 20 TeV, the electrical dipole moment must be of the order of 10–8 e cm.

Authors and Affiliations

E. Barradas-Guevara, J. L. Díaz-Cruz, O. G. Félix Beltrán, C. Arellano Celiz

Keywords

Related Articles

NaI(Tl) Scintillator's Response Functions for Point-like and Distributed Gamma-ray Sources

The response functions of a NaI(Tl) detectors have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like s...

Calcium Hardness Analysis of Water Samples Using EDXRF Technique

Calcium hardness of water samples has been determined using a method based upon the energy Dispersive X-ray fluorescence (eDXRF) technique for elemental analysis. the minimum detection limit for Ca has been found in the...

Nuclei Near and Far From β-Stability Line

Proton to neutron ratio around β-stability line presents an open challenge to the nuclear physicists. The prominent milestone in this regard isthe discovery of the superheavy elements, nuclear halos in the lightest neutr...

Effective Atomic Number Dependence of Radiological Parameters of Some Organic Compounds at 122 KeV Gamma Rays

Mass attenuation coefficient is a fundamental parameter of radiation interaction, from which the other radiological parameters like half Value Layer [HVL], tenth Value Layer [TVL], total atomic and electronic cross-secti...

An application of PIXE technique to Proto Crustal Rocks: Geo chemical evaluation of Granulitic Charnockites of Eastern Ghats, Andhrapradesh, India

In this work, PIXE has been used for a variety of Precambrian proto crustal rocks in the form of granulitic charnockites,Eastern Ghats AP,India. In previous study of exterior part of the charnockite hill elemental analys...

Download PDF file
  • EP ID EP569089
  • DOI 10.15415/jnp.2018.61006
  • Views 228
  • Downloads 0

How To Cite

E. Barradas-Guevara, J. L. Díaz-Cruz, O. G. Félix Beltrán, C. Arellano Celiz (2018). Annihilation of Dipolar Dark Matter: χχ→γγ. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(1), 33-38. https://europub.co.uk/articles/-A-569089