Assessment of effect of Different Impression Techniques on Dimensional Accuracy of Implant Definitive Casts: A Comparative Study

Journal Title: Journal of Advanced Medical and Dental Sciences Research - Year 2017, Vol 5, Issue 12

Abstract

Background: A passively fitting prosthesis is considered an essential prerequisite for maintaining osseointegration. This is related to the fact that dental implants, unlike natural teeth, lack the cushioning effect of periodontal fibers and cannot completely accommodate the demands of the superstructure.Aim: To comparatively evaluate the effect of different impression techniques on dimensional accuracy of implant definitive casts.Materials and method: The present study was conducted in the Department of Prosthodontics of the dental institution. For the study, a stainless steel model of maxillary arch with 4 internal connection implants with 4 mm diameter and 10.5 mm length in maxillary right canine (implant no: 1) lateral incisors (implants no: 2 and 3) and left first premolar (implant no: 4) areas were used. In this study, impressions were made via two techniques: Open tray with long impression copings and closed tray with short impression copings. To evaluate the accuracy of each impression technique, centers of implants on the master model were located in three dimensions and compared with the centers in the experimental casts. Results: We observed mean displacement of Implant no. 2 with technique 1 was 0.06 and technique 2 was 0.07. Mean displacement of Implant no. 3 with technique 1 was -0.04 and technique 2 was 0.16. Mean displacement of Implant no. 3 with technique 1 was 0.03 and technique 2 was 0.29.Conclusion: Within the limitations we conclude that there is no significant difference between open and closed tray impression technique on dimensional accuracy of implant definitive casts.

Authors and Affiliations

Nausheen Jajira, Rajat Khajuria, Sidhant Sudan, Tanvi Sudan, Priyanka Choudhary, Gurjot Sodhi

Keywords

Related Articles

Histopathological Assessment of Chronic Inflammatory Periapical Lesions- An in vivo Study

Background: Periapical lesions are universally present and apical periodontitis, peri- apical granuloma, peri- apical abscess and peri- apical cysts are common one. The present study aimed at histological findings in chr...

Assessment of cases of dengue fever by clinical and laboratory findings

Background: Dengue is the most common viral disease in humans. Every year about 50 - 100 million individuals are infected. Dengue is reported in both urban and rural area. The present study was conducted to assess the c...

LEFT VENTRICULAR DYSFUNCTION AFTER ACUTE MYOCARDIAL INFARCTION- A PROSPECTIVE STUDY

Background: Heart failure is an incessant complexity of myocardial localized necrosis. A few components, for example, recurrent myocardial ischemia, infarct size, ventricular remodeling, stunned myocardium, mechanical co...

Comparative Evaluation of Root Supported Over-Denture versus Root Supported Over-Denture with Precision Attachment

Introduction: Over-denture treatment concept is about the removable complete denture that overlies retained teeth, tooth roots, or dental implants. This treatment option is not a recent concept, and has been successfully...

Management of Biomedical Waste: Knowledge and Awareness Lacunae

Background: Biomedical Waste is perilous leading to many infections and thus its management is obligatory. Health care waste, due to its content of hazardous substances, poses serious threats to personal and environmenta...

Download PDF file
  • EP ID EP556332
  • DOI -
  • Views 88
  • Downloads 0

How To Cite

Nausheen Jajira, Rajat Khajuria, Sidhant Sudan, Tanvi Sudan, Priyanka Choudhary, Gurjot Sodhi (2017). Assessment of effect of Different Impression Techniques on Dimensional Accuracy of Implant Definitive Casts: A Comparative Study. Journal of Advanced Medical and Dental Sciences Research, 5(12), 115-118. https://europub.co.uk/articles/-A-556332