Assessment of Incurred Sample Reanalysis for Macromolecules to Evaluate Bioanalytical Method Robustness: Effects from Imprecision

Journal Title: The AAPS Journal - Year 2011, Vol 13, Issue 2

Abstract

Incurred sample reanalysis (ISR) is recommended by regulatory agencies to demonstrate reproducibility of validated methods and provide confidence that methods used in pharmacokinetic and toxicokinetic assessments give reproducible results. For macromolecules to pass ISR, regulatory recommendations require that two thirds of ISR samples be within 30% of the average of original and reanalyzed values. A modified Bland–Altman (mBA) analysis was used to evaluate whether total error (TE), the sum of precision and accuracy, was predictive of a method’s passing ISR and to identify potential contributing parameters for ISR success. Simulated studies determined minimum precision requirements for methods to have successful ISR and evaluated the relationship between precision and the probability of a method’s passing ISR acceptance criteria. The present analysis evaluated ISRs conducted for 37 studies involving ligand-binding assays (LBAs), with TEs ranging from 15% to 30%. An mBA approach was used to assess accuracy and precision of ISR, each with a threshold of 30%. All ISR studies met current regulatory criteria; using mBA, all studies met the accuracy threshold of 30% or less, but two studies (5%) failed to meet the 30% precision threshold. Simulation results showed that when an LBA has ≤15% imprecision, the ISR criteria for both the regulatory recommendation and mBA would be met in 99.9% of studies. Approximately 71% of samples are expected to be within 1.5 times the method imprecision. Therefore, precision appears to be a critical parameter in LBA reproducibility and may also be useful in identifying methods that have difficulty passing ISR.

Authors and Affiliations

Theingi M. Thway, Michael Eschenberg, Dominador Calamba, Chris Macaraeg, Mark Ma, Binodh DeSilva

Keywords

Related Articles

Deconvolution and IVIVC: Exploring the Role of Rate-Limiting Conditions

In vitro-in vivo correlations (IVIVCs) play an important role in formulation development and drug approval. At the heart of IVIVC is deconvolution, the method of deriving an in vivo “dissolution profile”...

Lung microdialysis—A powerful tool for the determination of exogenous and endogenous compounds in the lower respiratory tract (mini-review)

In vivo measurement of concentrations of drugs and endogenous substances at the site of action has become a primary focus of research. In this context the minimal invasive microdialysis (MD) technique has been increasing...

Time-and concentration-dependent penetration of doxorubicin in prostate tumors

The penetration of paclitaxel into multilayered solid tumors is time- and concentration-dependent, a result of the drug-induced apoptosis and changes in tissue composition. This study evaluates whether this tissue penetr...

Wet granulation fine particle ethylcellulose tablets: Effect of production variables and mathematical modeling of drug release

In the present study, the applicability of fine particle ethylcellulose (FPEC) to produce matrix tablets by a wet granulation technique was evaluated. The effect of various formulation and process variables, such as FPEC...

Pre-Existing Biotherapeutic-Reactive Antibodies: Survey Results Within the American Association of Pharmaceutical Scientists

The immunogenicity profile of a biotherapeutic is determined by a multitude of product and patient-related risk factors that can influence the observed incidence and clinical consequences of immunogenicity. Pre-existing...

Download PDF file
  • EP ID EP681310
  • DOI  10.1208/s12248-011-9271-z
  • Views 59
  • Downloads 0

How To Cite

Theingi M. Thway, Michael Eschenberg, Dominador Calamba, Chris Macaraeg, Mark Ma, Binodh DeSilva (2011). Assessment of Incurred Sample Reanalysis for Macromolecules to Evaluate Bioanalytical Method Robustness: Effects from Imprecision. The AAPS Journal, 13(2), -. https://europub.co.uk/articles/-A-681310