Effect of Modified Micro-Sand, Poly-Aluminium Chloride and Cationic Polymer on Coagulation-Flocculation Process of Landfill Leachate

Journal Title: Environment & Ecosystem Science (EES) - Year 2017, Vol 1, Issue 1

Abstract

Sanitary landfill leachate is considered as highly polluted wastewater, if without any treatment and discharge into water system will affect water quality. This study was carried out to assess the treatability of the semi-aerobic landfill leachate via coagulation-flocculation using poly-aluminum chloride (PAC), cationic polymer and modified micro sand. Leachate was collected from Pulau Burung Sanitary Landfill located in Penang, Malaysia. Coagulationflocculation was performed by using jar test equipment and the effect of pH, dose of coagulant and polymer toward removal of chemical oxygen demand (COD), color and suspended solid (SS) were examined. Micro sand also had been used in this study to compare settling time between coagulation-flocculation process with and without the aid of micro sand. The optimum pH, dose of coagulant (PAC) and dose of polymer (cationic) were achieved at 7.0, 1,000 mg/L and 8 mg/L, respectively. The dose of micro sand used for the settling time process is 300 mg/L. Results showed 52.66 % removal of COD, 97.16% removal of SS and 96.44% removal of color were obtained under optimum condition. The durations of settling time to settle down the sludge or particle that formed during coagulation-flocculation process were recorded at 1 minute (modified sand), 20 minutes (raw micro sand) and 45 minutes (without micro sand).

Authors and Affiliations

Nur Hanani Thaldiri, Marlia Mohd. Hanafiah, Azhar Abdul Halim

Keywords

Related Articles

EFFECT OF RHIZOBIUM INOCULATION WITH PHOSPHORUS AND NITROGEN FERTILIZER ON PHYSICO - CHEMICAL PROPERTIES OF THE GROUNDNUT SOIL

Low soil fertility status, nutritional imbalance and inappropriate agronomic practices are the major problems limiting the current production and yield of groundnut, therefore a study was conducted during 2015/2016 at th...

DETERMINING THE SENSITIVE CONSERVATIVE SITE IN KOLAH GHAZI NATIONAL PARK, IRAN, IN ORDER TO MANAGEMENT WILDLIFE BY USING GIS SOFTWARE

One of the basic keys in the conservation and management principle of protected region especially national parks is identifying the ecological resources of the region. Undoubtedly in each ecosystem, there are regions whi...

FMEA TECHNIQUES USED IN ENVIRONMENTAL RISK ASSESSMENT

Other industries or strategic installations cities after the industrialization process, a large percentage of urban land use, consciously or unconsciously to have been allocated. Investigation and detection of black spot...

UTILIZATION OF WASTEWATER FOR CORROSION PREVENTION OF CARBON STEEL PIPE USING SINGLE CHAMBER MICROBIAL FUEL CELLS

This study applies a concept Microbial Fuel Cells (MFCs) in a biological cathodic protection (CP) system. The biological CP uses the microbial properties of living microorganisms which are able to produce electrons and s...

COMPARATIVE HEAVY METAL UPTAKE AND PHYTOREMEDIATION POTENTIAL OF THREE JATROPHA SPECIES

The comparative metal uptake and phytoremediation capacity of Jatropha curcas, Jatropha gossypifolia, and Jatropha multifida in heavy metal contaminated soil from a dumpsite in Ibadan Nigeria were studied. Plants were tr...

Download PDF file
  • EP ID EP263792
  • DOI 10.26480/ees.01.2017.17.19
  • Views 137
  • Downloads 0

How To Cite

Nur Hanani Thaldiri, Marlia Mohd. Hanafiah, Azhar Abdul Halim (2017). Effect of Modified Micro-Sand, Poly-Aluminium Chloride and Cationic Polymer on Coagulation-Flocculation Process of Landfill Leachate. Environment & Ecosystem Science (EES), 1(1), 17-19. https://europub.co.uk/articles/-A-263792