Mechanical Prosthetic Valves and Pregnancy A therapeutic dilemma of anticoagulation

Journal Title: Sultan Qaboos University Medical Journal - Year 2014, Vol 14, Issue 4

Abstract

Choosing the best anticoagulant therapy for a pregnant patient with a mechanical prosthetic valve is controversial and the published international guidelines contain no clear-cut consensus on the best approach. Tis is due to the fact that there is presently no anticoagulant which can reliably decrease thromboembolic events while avoiding damage to the fetus. Current treatments include either continuing oral warfarin or substituting warfarin for subcutaneous unfractionated heparin or low-molecular-weight heparin (LMWH) in the frst trimester (6–12 weeks) or at any point throughout the pregnancy. However, LMWH, while widely-prescribed, requires close monitoring of the blood anti-factor Xa levels. Unfortunately, facilities for such monitoring are not universally available, such as within hospitals in developing countries. Tis review evaluates the leading international guidelines concerning anticoagulant therapy in pregnant patients with mechanical prosthetic valves as well as proposing a simplifed guideline which may be more relevant to hospitals in this region.

Authors and Affiliations

Prashanth Panduranga| Departments of Cardiology, Royal Hospital, Muscat, Oman, Mohammed El-Deeb| Departments of Cardiology, Royal Hospital, Muscat, Oman, Chitra Jha| Departments of Obstetrics & Gynaecology, Royal Hospital, Muscat, Oman

Keywords

Related Articles

Imaging of Small Bowel Obstruction following Gastric Bypass Surgery for Morbid Obesity A retrospective review

Tis study is a single institution retrospective evaluation of imaging fndings of small bowel obstruction (SBO) after retrocolic antegastric Roux-en-Y gastric bypass surgery for morbid obesity. Methods: Te radiological...

Comparison between Three Different Equations for the Estimation of Glomerular Filtration Rate in Omani Patients with Type 2 Diabetes Mellitus

Objectives: Estimated glomerular fltration rate (eGFR) is an important component of a patient’s renal function profle. Te Modifcation of Diet in Renal Disease (MDRD) equation and the Chronic Kidney DiseaseEpidemiology...

Increasing Incidence of Infants with Low Birth Weight in Oman

Tis review article provides an overview of the levels, trends and some possible explanations for the increasing rate of low birth weight (LBW) infants in Oman. LBW data from national health surveys in Oman, and publish...

Download PDF file
  • EP ID EP14494
  • DOI -
  • Views 279
  • Downloads 10

How To Cite

Prashanth Panduranga, Mohammed El-Deeb, Chitra Jha (2014). Mechanical Prosthetic Valves and Pregnancy A therapeutic dilemma of anticoagulation. Sultan Qaboos University Medical Journal, 14(4), 448-454. https://europub.co.uk/articles/-A-14494