PERBEDAAN KADAR HEMOGLOBIN METODE SIANMETHEMOGLOBIN DENGAN DAN TANPA SENTRIFUGASI PADA SAMPEL LEUKOSITOSIS

Journal Title: Medical Laboratory Technology Journal - Year 2015, Vol 1, Issue 2

Abstract

Examination of hemoglobin levels influenced leukocytosis sianmethemoglobin method that causes increased absorbance measurements of hemoglobin levels increased significantly and the false blood sample that has been diluted with a solution Drabkins in centrifugation at 3000 rpm for 10 minutes and then the absorbance of the supernatant was measured with a photometer at λ 546 nm. This study aimed to analyze the differences in hemoglobin level examination siamethemoglobin method with and without centrifugation at sample leukocytosis. This type of research is observational research laboratory. The study design was cross-sectional study. Samples were taken from the remaining blood samples of patients who have been examined leukositnya number more than 20,000 / uL with Hematology Analyzer (CEL-DYN Ruby) February-April 2014, and were divided into 4 groups based on criteria that group 1. leukocyte count of 20,000 / uL-29 999 / mL, group II. 30,000 / uL-39 999 / uL, the group III. 40,000 / uL-49,999 / uL, the group IV. More than 50,000 / uL. The number of samples taken were 20 samples of each group, a total sample of 80 samples. The analysis showed no significant difference in hemoglobin levels siamethemoglobin method with and without centrifugation at sample leukocytosis with a value of p = 0.000 less than 0.05 α. Leukocytosis Turbidity affects the difference in hemoglobin levels with and without centrifugation, the higher the number the greater the difference in leukocyte levels of hemoglobin, hemoglobin level examination results of the study based on the criteria of the number of leukocytes obtained by the difference in hemoglobin levels with and without centrifugation in group I. 0.22 ± 0.07 g / dL, group II 0.40 ± 0.22 g / dL, a group III. 0.44 ± 0.14 g / dL, Group IV. 0.85 ± 0.41 g / dL. The level of hemoglobin in the sample sianmethemoglobin method leukocytosis with more than 20,000 / uL need a centrifuge so that appropriate hemoglobin levels over the patient's clinical condition.

Authors and Affiliations

Keywords

Related Articles

PRODUK URIKASE DARI Bacillus sp. KONTAMINAN LABORATORIUM

Urease is an enzyme catalyst in the reaction of oxidation of uric acid into Allantoin. Oxidation of uric acid by the enzyme has become a basic principle of measurement of uric acid levels in the human body. This research...

SPUTUM QUALITY OF THE ANYTIME AND OUTSET FOR EXAMINATION ACID-RESISTANCE BACILLI

Diagnosis Tuberculosis (TB) can establish by microscopic examination of acid-resistant bacilli in the patient's sputum. Sputum quality greatly affects the diagnosis of TB, but the sputum collected by patients at communit...

PENGARUH SIMPLISIA BUNGA KENANGA (CANANGA ODORATA (LAMK). HOOK.) SEBAGAI MAT ELEKTRIK TERHADAP KNOCK-DOWN NYAMUK AEDES AEGYPTI

The main vector of dengue fever is Aedes aegypti. Ylang flower can be useful as an anti-mosquito, so in this study ylang flower botanicals chosen as rechargeable electric mat as an anti-mosquito Aedes aegypti. Objectives...

POTENSI EKSTRAK RIMPANG KENCUR (Kaempferia galanga L.) MENGHAMBAT PERTUMBUHAN Candida albicans

Candida albicans infection is the cause of candidiasis. Candidiasis treatment can be done with a variety of antifungal drugs, one of them is rhizome of kencur (Kaempferia galanga L.). The Rhizome of kencur is selected as...

HUBUNGAN DOSIS TEPUNG GEMBILI (Dioscorea esculenta) DENGAN TINGKAT EKSPRESI ENZIM Ampk-α2 PADA MODEL TIKUS DIABETES MELITUS

Alternative methods of controlling glucose levels in patients with diabetes is by type of food, either by utilizing yam flour. At the flour contained inulin and resistant starch that can activate the enzyme AMPK-α2. Acti...

Download PDF file
  • EP ID EP414297
  • DOI -
  • Views 180
  • Downloads 0

How To Cite

(2015). PERBEDAAN KADAR HEMOGLOBIN METODE SIANMETHEMOGLOBIN DENGAN DAN TANPA SENTRIFUGASI PADA SAMPEL LEUKOSITOSIS. Medical Laboratory Technology Journal, 1(2), -. https://europub.co.uk/articles/-A-414297