RISK ANALYSIS EVALUATION OF PIROXICAM 20MG CAPSULES MANUFACTURE PROCESS BY FMEA TECHNIQUE

Journal Title: International Journal of Drug Regulatory Affairs - Year 2018, Vol 6, Issue 1

Abstract

This paper presents an application of FMEA (Failure Mode and Effects Analysis) on the manufacturing process of Piroxicam 20mg capsules, with the objective of identifying possible failures and creates subsidies for improvement of the production stages. Brainstorming or Collaborative critical analysis was used as a tool to collect information and support FMEA’s application. After the risk analysis, evaluation of the production process using FMEA, manipulation and secondary packaging were found to be the critical stages in the production process necessary for implementation of actions in order to mitigate the risks.

Authors and Affiliations

Cardoso Priscila, Marotta Flávia, Siqueira Kelen

Keywords

Related Articles

SOFTWARE AS MEDICAL DEVICE

The use of software in a medical device allows the manufacturer to concentrate on the application needed to run device-specific functions. The medical device manufacturer using software generally neglect software life cy...

PATENT V/S MONOPOLY-A CASE STUDY

Provisions of Compulsory License balance this law between interest of Inventor & public as through these provisions License can be provided to others if the invention did not use sufficiently for Public. In case of medic...

CURRENT REGULATION OF MEDICAL GASES IN INDIA AND FUTURE ASPECTS

Generally medical gases are administered or supplied directly to the patients. They should be manufactured and transferred with the highest quality possible as per standards and limits decided by the different regulatory...

Understanding the globally harmonized system of classification and Labeling of Chemicals-The Purple Book

Global Harmonized System (GHS), relating to hazard chemicals, is a process of making a regulation among countries uniform to the extent possible so as to benefit an industry to export its products to several countries wi...

SELF-MEDICATION IN RELATION TO HEALTH LOCUS OF CONTROL

Present study was conducted to examine the association of self- medication and health locus of control. It was also intended to know the health problems for which people do self – medication and the medicines which are m...

Download PDF file
  • EP ID EP329166
  • DOI 10.22270/ijdra.v6i1.215
  • Views 89
  • Downloads 0

How To Cite

Cardoso Priscila, Marotta Flávia, Siqueira Kelen (2018). RISK ANALYSIS EVALUATION OF PIROXICAM 20MG CAPSULES MANUFACTURE PROCESS BY FMEA TECHNIQUE. International Journal of Drug Regulatory Affairs, 6(1), 19-25. https://europub.co.uk/articles/-A-329166