10-MV X-ray dose calculation in water for MLC and wedge fields using a convolution method with X-ray spectra reconstructed as a function of off-axis distance

Journal Title: Journal of Radiology and Imaging - Year 2017, Vol 2, Issue 3

Abstract

Purposes: This paper highlights a 10-MV X-ray convolution dose calculation method in water using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of the off-axis distance for a linear accelerator equipped with pairs of upper and lower jaws, a multileaf collimator (MLC) and a wedge filter. Methods: The reconstructed X-ray spectra set was composed of 11 energy bins. To estimate the in-air beam intensities at points on the isocenter plane for an MLC field, we employed an MLC leaf-field output subtraction method, using an extended radiation source on each of the X-ray target and the flattening filter as well as simplified two-dimensional plates to simulate the three-dimensional jaws and MLC structures. A special correction factor was introduced for nonuniform incident beam intensities, particularly produced at MLC fields. The in-phantom dose calculation was performed by treating the phantom, the wedge filter, the wedge holder and the MLC as parts of a unified irradiated body, where we proposed to use a special factor for the density scaling theorem within the unified irradiated body. Conclusions: The phantom dose was generally separated into nine dose-components: The primary and scatter dose-components produced in the phantom; the primary and scatter dose-components emanating from the wedge, the wedge holder and the MLC; and the electron contamination dose-component. From the calculated and measured percentage depth dose (PDD) and off-center ratio (OCR) datasets, we may conclude that the convolution method can achieve accurate dose calculations even under MLC and/or wedge filtration.

Authors and Affiliations

Iwasaki A, Kimura S, Sutoh K, Kamimura K, Sasamori M, Seino M, Komai F, Takagi M, Terashima S, Hosokawa Y, Saitoh H, Miyazawa M

Keywords

Related Articles

MRI system scoring for differentiation of malignant versus benign stricture of the common bile duct

The purpose of this study was to evaluate the ability of magnetic resonance imaging (MRI) to differentiate between malignant and benign strictures of the common bile duct by using a scoring system. MRI scans of 34 patien...

Point of care ultrasound in cardiac arrest: A case report of PE in PEA arrest

Bedside ultrasound has become an integral part of cardiac arrest resuscitation, enabling the provider to identify potentially reversible conditions in real time. In the setting of pulmonary embolism, bedside ultrasound c...

Reduction of radiation dose in adult CT-guided musculoskeletal procedures

Objective: We examine the effect of manually reducing CT scanner tube voltage (kVp) and current (mA) on patient radiation dose and procedural success during CT-guided musculoskeletal procedures on adults. We hypothesize...

Clinical evaluation of near-infrared light transillumination (NIRT) as an interproximal caries detection tool in a large sample of patients in a private practice

Background: A study has been carried out in order to evaluate in vivo the diagnostic performance of near-infrared light transillumination (NIRT) compared to digital radiographic examination (RE) in the detection of class...

The hydrocele of canal of Nuck: Case report and review of the literature

The hydrocele of the canal of Nuck is a rare condition that results from the failure of obliteration of the distal portion of evaginated parietal peritoneum within the inguinal canal which forms a sac containing fluid. I...

Download PDF file
  • EP ID EP553956
  • DOI 10.14312/2399-8172.2017-4
  • Views 49
  • Downloads 0

How To Cite

Iwasaki A, Kimura S, Sutoh K, Kamimura K, Sasamori M, Seino M, Komai F, Takagi M, Terashima S, Hosokawa Y, Saitoh H, Miyazawa M (2017). 10-MV X-ray dose calculation in water for MLC and wedge fields using a convolution method with X-ray spectra reconstructed as a function of off-axis distance. Journal of Radiology and Imaging, 2(3), 14-35. https://europub.co.uk/articles/-A-553956