3D Buoyancy Induced Heat Transfer in Triangular Solar Collector Having a Corrugated Bottom Wall

Journal Title: Engineering, Technology & Applied Science Research - Year 2018, Vol 8, Issue 2

Abstract

A numerical study of the natural convection heat transfer and fluid flow in 3D triangular solar collector having a corrugated bottom wall has been carried out using finite volume method. The aim of the study is to investigate how buoyancy forces influence airflow and temperature patterns inside the collector heated from below and cooled on its inclined walls while vertical ones are assumed to be perfect thermal insulators. Rayleigh number is the main parameter which changes from 103 to 105 and Prandtl number is fixed at Pr=0.71. Results are reported in terms of particles trajectories, iso-surfaces of temperature, velocity magnitude and mean Nusselt number. It has been found that the flow structure is sensitive to the value of Rayleigh number and that heat transfer is enhanced with increasing of this parameter.

Authors and Affiliations

W. Aich

Keywords

Related Articles

Comparative Investigation of Pollution Accumulation and Natural Cleaning for Different HV Insulators

High Voltage insulators are scattered throughout any HV network and a single insulator fault may cause an excessive outage. Reliability is a key issue for electric power systems and fault-free performance of insulators g...

A Low Cost Automated Weather Station for Real Time Local Measurements

In this paper, we present an automated weather station for real time and local measurements, based on an embedded system that continuously measures several weather factors such as temperature, humidity, barometric pressu...

Production of Hydrogen from Poly Ethylene Terephthalate (PET) using CT 434 ZSM-5 Catalyst at Considerably Low Temperatures

The production of hydrogen from Poly Ethylene Terephthalate (PET) using CT 434 ZSM-5 is investigated in this research study. Gas chromatography equipped with a thermal conductivity detector is used to detect the amount o...

Analysis of D2D Communication System Over κ-μ Shadowed Fading Channel

Outage performance of a device-to-device (D2D) communication system in the presence of co-channel interference (CCI) is analyzed in this paper. Channels for the D2D and CCI signals are assumed to be κ-μ shadowed faded. M...

Numerical Study of Natural Convective Heat and Mass Transfer in an Inclined Porous Media

In this study, two dimensional natural convection heat and mass transfer generated in an inclined rectangular porous cavity filled with Newtonian fluid has been investigated numerically. The cavity is heated and cooled a...

Download PDF file
  • EP ID EP156306
  • DOI -
  • Views 255
  • Downloads 0

How To Cite

W. Aich (2018). 3D Buoyancy Induced Heat Transfer in Triangular Solar Collector Having a Corrugated Bottom Wall. Engineering, Technology & Applied Science Research, 8(2), -. https://europub.co.uk/articles/-A-156306