Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography

Journal Title: Engineering, Technology & Applied Science Research - Year 2011, Vol 1, Issue 1

Abstract

Nuclear medicine (SPECT and PET) provides functional information, which is complementary to the structural. In cancer imaging radiopharmaceuticals allow visualization of cancer cells functionality, thus small cell population can be imaged. This allows early diagnosis, as well as fast assessment of response to therapy. Our system is a single head gamma camera based on an R3292 position sensitive photomultiplier tube (PSPMT), coupled to a 10cm in diameter CsI:Tl crystal. We have assessed two CsI:Tl crystals with pixel size of 2x2mm2 and 3x3mm2 respectively. Three collimators were tested: a) a hexagonal, 1.1mm in diameter, general purpose parallel hole collimator b) a 1mm pinhole and c) a 2mm pinhole. Systems were tested using capillary phantoms. All measurements were carried out in photon counting mode with gamma radiation produced by 99mTc. Using the 2x2mm2 crystal and the 1mm pinhole collimator - a resolution better than 1mm was achieved. This allows very detailed imaging of small animals. Using the 3x3mm2 and the 2mm pinhole collimator a resolution of 1.3mm was possible with suitable sensitivity for breast imaging. Those results indicate that this system is suitable for animal and breast studies. The next step will be clinical evaluation of the camera.

Authors and Affiliations

S. David, M. Georgiou, E. Fysikopoulos, G. Loudos

Keywords

Related Articles

Improving the Bond Strength of Rice Husk Ash Concrete by Incorporating Polymer: A New Approach

This paper gives an insight of how to improve the bond strength of cement in which concrete is replaced with rice husk ash. A concrete mix was prepared and was used in different types of mixes i.e. Control Mix, 10% cemen...

Fuzzy Sliding Mode Control of DC-DC Boost Converter

A sliding mode fuzzy control method which combines sliding mode and fuzzy logic control for DC-DC boost converter is designed to achieve robustness and better performance. A fuzzy sliding mode controller in which sliding...

Optimum Shape Design of Metal-Enclosed 550 kV Disconnectors Based on Response Surface Method and Finite Element Analysis

In this paper, the optimum shape design of 550 kV disconnectors in Gas Insulated Switchgears (GIS) are firstly presented employing the Finite Element Method (FEM) for electric field analysis coupled with an optimal desig...

Interface Structure and Elements Diffusion of As-Cast and Annealed Ductile Iron/Stainless Steel Bimetal Castings

Bimetal casting is considered to a promising technique for the production of high performance function materials. Heat treatment process for bimetal castings became an essential tool for improving interface structure and...

Influence of Material and Geometrical Properties of Permanent Magnets on Cogging Torque of BLDC

Aim of this study is to investigate the influence of both material and geometrical properties of surface mounted permanent magnets (PM) on cogging torque of a brushless DC motor (BLDC) by means of numerical modeling base...

Download PDF file
  • EP ID EP84377
  • DOI -
  • Views 354
  • Downloads 0

How To Cite

S. David, M. Georgiou, E. Fysikopoulos, G. Loudos (2011). Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography. Engineering, Technology & Applied Science Research, 1(1), -. https://europub.co.uk/articles/-A-84377