Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography
Journal Title: Engineering, Technology & Applied Science Research - Year 2011, Vol 1, Issue 1
Abstract
Nuclear medicine (SPECT and PET) provides functional information, which is complementary to the structural. In cancer imaging radiopharmaceuticals allow visualization of cancer cells functionality, thus small cell population can be imaged. This allows early diagnosis, as well as fast assessment of response to therapy. Our system is a single head gamma camera based on an R3292 position sensitive photomultiplier tube (PSPMT), coupled to a 10cm in diameter CsI:Tl crystal. We have assessed two CsI:Tl crystals with pixel size of 2x2mm2 and 3x3mm2 respectively. Three collimators were tested: a) a hexagonal, 1.1mm in diameter, general purpose parallel hole collimator b) a 1mm pinhole and c) a 2mm pinhole. Systems were tested using capillary phantoms. All measurements were carried out in photon counting mode with gamma radiation produced by 99mTc. Using the 2x2mm2 crystal and the 1mm pinhole collimator - a resolution better than 1mm was achieved. This allows very detailed imaging of small animals. Using the 3x3mm2 and the 2mm pinhole collimator a resolution of 1.3mm was possible with suitable sensitivity for breast imaging. Those results indicate that this system is suitable for animal and breast studies. The next step will be clinical evaluation of the camera.
Authors and Affiliations
S. David, M. Georgiou, E. Fysikopoulos, G. Loudos
Reduced Feature Set for Emotion Based Spoken Utterances of Normal and Special Children Using Multivariate Analysis and Decision Trees
The current paper deals with the use of multivariate data analysis and decision tree methods in order to reduce the feature set for the normal and special children speech in four different emotions: anger, happiness, neu...
Study of Four Element Microstrip Antenna Array Using Patch Type Electromagnetic Band Gap Structure
This paper describes enhancements in the performance of four element microstrip antenna array. The conventional microstrip antenna array is producing gain equal to 6.81dB. With the introduction of U shape patch type elec...
A Hybrid Data Mining Method for Customer Churn Prediction
The expenses for attracting new customers are much higher compared to the ones needed to maintain old customers due to the increasing competition and business saturation. So customer retention is one of the leading facto...
Critical Factors of E-Learning Adoption and Acceptance in Pakistan: A Literature Review
This review paper examines the prior studies on critical factors of e-learning adoption in Pakistan. The search terms identified 40 papers reporting 25 conceptual and qualitative and 15 quantitative evidence about the e-...
Modeling for Development of Simulation Tool: Impact of TCSC on Apparent Impedance Seen by Distance Relay
The impact of thyristor controlled series capacitor (TCSC) on distance protection relays in transmission lines is analyzed in this paper. Voltage and current data are measured and collected at the relay locations to calc...