Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography

Journal Title: Engineering, Technology & Applied Science Research - Year 2011, Vol 1, Issue 1

Abstract

Nuclear medicine (SPECT and PET) provides functional information, which is complementary to the structural. In cancer imaging radiopharmaceuticals allow visualization of cancer cells functionality, thus small cell population can be imaged. This allows early diagnosis, as well as fast assessment of response to therapy. Our system is a single head gamma camera based on an R3292 position sensitive photomultiplier tube (PSPMT), coupled to a 10cm in diameter CsI:Tl crystal. We have assessed two CsI:Tl crystals with pixel size of 2x2mm2 and 3x3mm2 respectively. Three collimators were tested: a) a hexagonal, 1.1mm in diameter, general purpose parallel hole collimator b) a 1mm pinhole and c) a 2mm pinhole. Systems were tested using capillary phantoms. All measurements were carried out in photon counting mode with gamma radiation produced by 99mTc. Using the 2x2mm2 crystal and the 1mm pinhole collimator - a resolution better than 1mm was achieved. This allows very detailed imaging of small animals. Using the 3x3mm2 and the 2mm pinhole collimator a resolution of 1.3mm was possible with suitable sensitivity for breast imaging. Those results indicate that this system is suitable for animal and breast studies. The next step will be clinical evaluation of the camera.

Authors and Affiliations

S. David, M. Georgiou, E. Fysikopoulos, G. Loudos

Keywords

Related Articles

A Novel Image Stream Cipher Based On Dynamic Substitution

Recently, many chaos-based stream cipher algorithms have been developed. Traditional chaos stream cipher is based on XORing a generated secure random number sequence based on chaotic maps (e.g. logistic map, Bernoulli Ma...

Experimental Implementation of a Low-Cost Single Phase Five-Level Inverter for Autonomous PV System Applications Without Batteries

This paper presents the design and the implementation of a low-cost single phase five-level inverter for photovoltaic applications. The proposed multilevel inverter is composed of a simple boost converter, a switched-cap...

Development of an Amorphous Silica from Rice Husk Waste

This article presents a study on the development of amorphous silica from Rice Husk (RH) waste. For ascertaining the optimum proportion of temperature and burning duration required for the development of an amorphous sil...

EgoSENSE: A Framework for Context-Aware Mobile Applications Development

This paper presents a context-aware mobile framework (or middleware), intended to support the implementation of context-aware mobile services. The overview of basic concepts, architecture and components of context-aware...

Design and Analysis of Multi-Phase BLDC Motors for Electric Vehicles

This paper presents a design and analysis of multi-phase brushless direct current (BLDC) motor for electric vehicles (EV). In this work, hub-wheels having 110Nm, 900rpm rated values have been designed for the proposed EV...

Download PDF file
  • EP ID EP84377
  • DOI -
  • Views 401
  • Downloads 0

How To Cite

S. David, M. Georgiou, E. Fysikopoulos, G. Loudos (2011). Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography. Engineering, Technology & Applied Science Research, 1(1), -. https://europub.co.uk/articles/-A-84377