Comparative Assessment of Gate Drive Control Schemes in High Frequency Converter

Journal Title: Engineering, Technology & Applied Science Research - Year 2011, Vol 1, Issue 4

Abstract

Several gate drive control schemes are simulated and the results show that the Fixed Duty ratio (FDR) can help drive synchronous rectifier buck converter (SRBC) correctly with low dead time and hence reduce body diode conduction loss. Even though FDR is prone to cross-conduction effects, the design is simple. Apart from that, Adaptive Gate Delay (AGD) and Predictive Gate Delay (PGD) control schemes have also shown high level of efficiency. However, AGD generates more losses. Even though the total switching loss in PGD has not improved much of only 1 %, more than 82 % efficiency has been achieved in spite of the advantage in FDR and AGD schemes.

Authors and Affiliations

N. Z. Yahaya, K. M. Begam, M. Awan

Keywords

Related Articles

Statistical Magnitude Analysis and Distance Determination of the Nearby F8V Stars

The present paper is of three folds. First, to provide some basic descriptive statistics parameters for the apparent and absolute magnitudes of the nearby stars of spectral type F8V stars. Second, to establish the freque...

Enhanced Model For Evaluating Information System Success: Determining Critical Criteria

The purpose of this study is to enhance the DeLone and McLean information system success by adding a SERVQUAL instrument to evaluate the service quality dimension. An integrated model for evaluating the information syste...

Kinetic Modeling of Dye Effluent Biodegradation by Pseudomonas Stutzeri

Dye industry waste water is difficult to treat because of the presence of dyes with complex aromatic structure. In this research study, the biodegradation studies of dye effluent were performed utilizing Pseudomonas stut...

Perspectives on a Big Data Application: What Database Engineers and IT Students Need to Know

Cloud Computing and Big Data are important and related current trends in the world of information technology. They will have significant impact on the curricula of computer engineering and information systems at universi...

Implementation of Close Loop Speed Control with VVVF Control and Slip Regulation on LIM

Open loop VVVF control has the disadvantage of low output torque when working at low frequency and poor speed precision at different load conditions.Various performance-improving schemes have been proposed for the basic...

Download PDF file
  • EP ID EP84797
  • DOI -
  • Views 353
  • Downloads 0

How To Cite

N. Z. Yahaya, K. M. Begam, M. Awan (2011). Comparative Assessment of Gate Drive Control Schemes in High Frequency Converter. Engineering, Technology & Applied Science Research, 1(4), -. https://europub.co.uk/articles/-A-84797