A Comparative Analysis Between Optimized and Baseline High Pressure Compressor Stages Using Tridimensional Computational Fluid Dynamics

Journal Title: Engineering, Technology & Applied Science Research - Year 2015, Vol 6, Issue 4

Abstract

Re-vamping of industrial turbo-machinery is commonplace in the oil and gas industry in applications where subterranean combustion is used for oil extraction. The current case study refers to such an industrial compressor re-vamping, using a state of the art 3D fully viscous CFD methodology coupled with artificial neural networks (ANNs) and genetic algorithms (GA). The ANN is used to establish correlations within a database of CFD simulations of geometrical variations of the original rotor and the GA uses those correlations to estimate an optimum. The estimate is then tested with the same CFD method and the results are fed back into the database, increasing the accuracy of the ANN correlations. The process is reiterated until the optimum estimated by the GA is confirmed with the CFD simulations. The resulting geometry is superior to the original in terms of efficiency and pressure ratio as well as the range of stabile operation, as confirmed by the successful implementation in the field. In this paper we present an analysis of why the optimized geometry achieves superior performances to the original one. Further work will present comparison between the detailed experimental data and CFD.

Authors and Affiliations

V. Dragan, I. Malael, B. Gherman

Keywords

Related Articles

Estimation of Length and Order of Polynomial-based Filter Implemented in the Form of Farrow Structure

Digital polynomial-based interpolation filters implemented using the Farrow structure are used in Digital Signal Processing (DSP) to calculate the signal between its discrete samples. The two basic design parameters for...

State-Space Modeling and Performance Analysis of Variable-Speed Wind Turbine Based on a Model Predictive Control Approach

Advancements in wind energy technologies have led wind turbines from fixed speed to variable speed operation. This paper introduces an innovative version of a variable-speed wind turbine based on a model predictive contr...

Investigating Appropriate Financing Methods in Collaborative Projects of Water and Wastewater with AHP Approach

A mix of public and private funding is employed worldwide to enable the construction of large public projects and even, in some cases, the work of public services. In this study, the selected methods of financing of part...

Risk Attributes, Influencing the Time and Cost Overrun in Joint Venture Construction Projects of Pakistan

Business collaborations formed by construction contractors to enhance their abilities and effectiveness in large construction projects are known as construction joint ventures (CJVs). It is widely used as a way of mergin...

Construction and Demolition Waste Management (Tehran Case Study)

Increasing building construction raises concerns about construction and demolition (C&D) waste management. To assess this issue the building components, the collection schemes, their recycling and disposal should be inve...

Download PDF file
  • EP ID EP110083
  • DOI -
  • Views 252
  • Downloads 0

How To Cite

V. Dragan, I. Malael, B. Gherman (2015). A Comparative Analysis Between Optimized and Baseline High Pressure Compressor Stages Using Tridimensional Computational Fluid Dynamics. Engineering, Technology & Applied Science Research, 6(4), -. https://europub.co.uk/articles/-A-110083