A COMPARATIVE EVALUATION OF FLEXURAL FATIGUE RESISTANCE OF PROTAPER NEXT AND PROFILE VORTEX: AN IN-VITRO STUDY.

Abstract

Background: Introduction of nickel titanium file system for root canal therapy has changed the conventional approach but instrument fracture in curved and narrow root canal still remains a challenge for operator. Aim & objective: This study aimed to compare the cyclic fatigue fracture resistance of two recent rotary Ni Ti file systems: Protaper Next and Profile Vortex file system. Methodology:The cyclic fatigue testing was conducted with the files rotating freely at an angle of curvature 60⁰ with maximum radius of curvature at 5mm from the tip. Ten endodontic rotary files were selected in each of the two groups to be tested. The files were rotated at 400 rpm using the Tri auto mini endomotor with handpiece set at 2.5 Torque, until the fracture occurred. The time until fracture was recorded in seconds by using a stopwatch, and the number of rotations till fracture was then calculated and results were then statistically analyzed. Result:The results showed Protaper Next performed significantly (P < 0.001)better and had good survival time than Profile Vortex rotary file system during cyclic fatigue testing.Conclusion:It was concluded that Protaper Next files had greater resistance to cyclic fatigue than Profile Vortex file system. Keywords:CyclicFatigue, Flexural fracture, Flexural resistance.

Authors and Affiliations

Dr. Akanksha Bhatt

Keywords

Related Articles

A Review on Acacia species of therapeutics importance

Plants are used medicinally in different countries and are a source of many potent and powerful drugs. Various plants of Acacia species were claimed to possess traditional medicinal activities .Different parts of plant h...

STUDY OF ADSORPTION OF DRUG AND CALCULATION OF FREUNDLICH ADSORPTION ISOTHERM

Adsorption is the adhesion of atoms, ions, or molecules from a gas, liquid, or dissolved solid to a surface. Adsorption is a surface-based process while absorption involves the whole volume of the material. The term sorp...

ISOLATION AND CHARACTERIZATION OF A FLAVONOID FROM ETHANOLIC EXTRACT OF ALTERNANTHERA SESSILIS LINN.

This study was performed to isolate and characterize the flavonoid present in Alternanthera sessilis Linn. Direct soxhlet extraction process was adopted for extraction by using 95% ethanol and vacuum evaporator was used...

A REVIEW ON FORMULATIONS AND EVALUATION OF FILM COATED IMMEDIATE RELEASE TABLETS OF PIRACETAM

Tablets are solid preparations each containing a single dose of one or more active substances with or without excipients usually obtained by compressing uniform volumes of particles. An immediate release dosage form allo...

THE SUSCEPTIBILITY PATTERN AND EFFICACY OF COMMERCIALLY AVAILABLE DISINFECTANTS TO Staphylococcus aureus ISOLATED FROM BUTCHERS’ TABLE IN ABAKALIKI MEAT MARKET".

This study investigated the susceptibility pattern and efficacy of commercially available disinfectants to Staphylococcus aureus isolated from butchers’ tables in Abakaliki meat market. Butchers’ tables were swabbed usin...

Download PDF file
  • EP ID EP416726
  • DOI -
  • Views 133
  • Downloads 0

How To Cite

Dr. Akanksha Bhatt (2017). A COMPARATIVE EVALUATION OF FLEXURAL FATIGUE RESISTANCE OF PROTAPER NEXT AND PROFILE VORTEX: AN IN-VITRO STUDY.. International Journal of Pharmaceutical and Biological Science Archive, 5(1), 81-84. https://europub.co.uk/articles/-A-416726