A COMPARATIVE STUDY BETWEEN INTRAOPERATIVE CLINICAL AND POSTOPERATIVE RADIOLOGICAL MEASUREMENT OF DISTANCE BETWEEN TIP OF GREATER TROCHANTER TO CENTER OF FEMORAL HEAD IN OPERATED CASES OF HIP HEMIARTHROPLASTY

Journal Title: Journal of Evolution of Medical and Dental Sciences - Year 2018, Vol 7, Issue 52

Abstract

BACKGROUND Hip joint is a polyaxial ball and socket joint. At different stages of gait cycle, joint reaction forces at the hip joint depend on abductor leaver arm which is function of neck length (Offset), neck shaft angle and body weight. During Arthroplasty operation of hip, femoral offset measurement and its restoration to anatomical limit is important. In our study, we have measured the femoral neck length, between two fixed bony points, from the tip of greater trochanter (GT) to the center of the femoral head peroperatively and again post-operatively, from the true size x-ray of the replaced femoral head. We compared this measurement with the postoperative x-ray of normal side hip, to compare, how far normal offset is achieved after operating with various prosthesis (fixed bipolar prosthesis and modular prosthesis) available in the Indian scenario. MATERIALS AND METHODS This is a prospective, comparative study on presentation at in-patient department (IPD). Total 53 patient (22 male and 31 female) above 60 years of age, admitted at our institution ‘Ramakrishna Mission Seva Prathistan (VIMS)’ in the year 2015-16, with intracapsular fracture neck femur of either right or left side were studied. Per-operative measurement was taken during hemiarthroplasty operation using fixed bipolar prosthesis or modular prosthesis (cemented/un-cemented) available in the Indian market. Post-operative measurement taken in the true size x-ray of two fixed points on the operated and normal side. Limb length was measured clinically. The values obtained were compared to establish how far the normal anatomical offset is achieved after hemiarthroplasty operation by using prosthesis manufactured by different companies in India. RESULTS Intraoperative measurement of distance between tip of GT and center of femoral head corresponded with the measurement taken from tip of GT to the prosthetic femoral head. This signifies that we have successfully corrected the offset with available prosthesis with correct surgical technique. There is no significant difference in the postoperative true size x-ray of distance between tip of GT to the center of prosthetic femoral head and the tip of GT with center of femoral head of normal side. CONCLUSION Our study results shows that by opting correct surgical technique and appropriate neck resection, currently available prosthesis (FBP & MBP) in our country can achieve desired neck offset length in comparison to the normal hip and had no significant limb length discrepancy.

Authors and Affiliations

Hiranmoy Deb, Sunny Kumar Mallick

Keywords

Related Articles

ASSOCIATION OF PARENTAL SOCIOECONOMIC STATUS AND AGE WITH CONSANGUINITY- A SYSTEMATIC REVIEW

BACKGROUND Consanguineous marriages are common in India, particularly in southern states and Muslim communities. As far as worldwide scenario is concerned in North and sub-Saharan Africa as well as West, Central and Sout...

MISSING COPPER T WITH UTERINE PERFORATION: TWO CASE REPORTS

Intrauterine devices are currently one of the most popular reversible contraception methods used worldwide. IUCD is common method of contraception among women because of its low cost and high efficacy. Though relativ...

 DISTAL ARTHROGRYPOSIS MULTIPLEX CONGENITA WITH MULTISYSTEM INVOLVEMENT: A CASE REPORT

 Arthrogryposis Multiplex Congenita (AMC) is an uncommon but easily recognizable syndrome of musculoskeletal system. All four extremities and the trunk may be affected. The hallmark of this entity is the lack of a...

A STUDY ON THE CLINICAL PROFILES OF PATIENTS WITH LEPRA REACTIONS TYPE 1 AND TYPE 2 REACTIONS COMING TO THE OPD AT TERTIARY CARE CENTRE IN WESTERN UTTAR PRADESH

BACKGROUND Type 1 reaction is a Type IV Hypersensitivity reaction in Borderline leprosy occurring in early treatment, also called reversal reaction affecting those with Borderline leprosy upgrading to tuberculoid type or...

 A CLINICAL STUDY OF MORBIDITY AND MORTALITY PATTERN OF LATE PRETERM INFANTS AT SNCU, WARANGAL

 OBJECTIVE A clinical study of morbidity and mortality pattern of late preterm infants in comparison with term infants. STUDY DESIGN Prospective observational study. SETTING SNCU, Mahatma Gandhi Memorial Hos...

Download PDF file
  • EP ID EP550498
  • DOI 10.14260/jemds/2018/1227
  • Views 66
  • Downloads 0

How To Cite

Hiranmoy Deb, Sunny Kumar Mallick (2018). A COMPARATIVE STUDY BETWEEN INTRAOPERATIVE CLINICAL AND POSTOPERATIVE RADIOLOGICAL MEASUREMENT OF DISTANCE BETWEEN TIP OF GREATER TROCHANTER TO CENTER OF FEMORAL HEAD IN OPERATED CASES OF HIP HEMIARTHROPLASTY. Journal of Evolution of Medical and Dental Sciences, 7(52), 5543-5548. https://europub.co.uk/articles/-A-550498