A COMPARATIVE STUDY BETWEEN INTRAOPERATIVE CLINICAL AND POSTOPERATIVE RADIOLOGICAL MEASUREMENT OF DISTANCE BETWEEN TIP OF GREATER TROCHANTER TO CENTER OF FEMORAL HEAD IN OPERATED CASES OF HIP HEMIARTHROPLASTY

Journal Title: Journal of Evolution of Medical and Dental Sciences - Year 2018, Vol 7, Issue 52

Abstract

BACKGROUND Hip joint is a polyaxial ball and socket joint. At different stages of gait cycle, joint reaction forces at the hip joint depend on abductor leaver arm which is function of neck length (Offset), neck shaft angle and body weight. During Arthroplasty operation of hip, femoral offset measurement and its restoration to anatomical limit is important. In our study, we have measured the femoral neck length, between two fixed bony points, from the tip of greater trochanter (GT) to the center of the femoral head peroperatively and again post-operatively, from the true size x-ray of the replaced femoral head. We compared this measurement with the postoperative x-ray of normal side hip, to compare, how far normal offset is achieved after operating with various prosthesis (fixed bipolar prosthesis and modular prosthesis) available in the Indian scenario. MATERIALS AND METHODS This is a prospective, comparative study on presentation at in-patient department (IPD). Total 53 patient (22 male and 31 female) above 60 years of age, admitted at our institution ‘Ramakrishna Mission Seva Prathistan (VIMS)’ in the year 2015-16, with intracapsular fracture neck femur of either right or left side were studied. Per-operative measurement was taken during hemiarthroplasty operation using fixed bipolar prosthesis or modular prosthesis (cemented/un-cemented) available in the Indian market. Post-operative measurement taken in the true size x-ray of two fixed points on the operated and normal side. Limb length was measured clinically. The values obtained were compared to establish how far the normal anatomical offset is achieved after hemiarthroplasty operation by using prosthesis manufactured by different companies in India. RESULTS Intraoperative measurement of distance between tip of GT and center of femoral head corresponded with the measurement taken from tip of GT to the prosthetic femoral head. This signifies that we have successfully corrected the offset with available prosthesis with correct surgical technique. There is no significant difference in the postoperative true size x-ray of distance between tip of GT to the center of prosthetic femoral head and the tip of GT with center of femoral head of normal side. CONCLUSION Our study results shows that by opting correct surgical technique and appropriate neck resection, currently available prosthesis (FBP & MBP) in our country can achieve desired neck offset length in comparison to the normal hip and had no significant limb length discrepancy.

Authors and Affiliations

Hiranmoy Deb, Sunny Kumar Mallick

Keywords

Related Articles

 OBSTRUCTIVE JAUNDICE: A CLINICAL STUDY

 BACKGROUND Jaundice is a frequent manifestation of biliary tract disorders and evaluation of obstructive jaundice is a common problem faced by general surgeons. Obstructive jaundice of varied aetiology is one o...

A COMPARATIVE STUDY OF ECHOCARDIOGRAPHIC PARAMETERS IN INDIAN PREGNANT AND NONPREGNANT WOMEN

BACKGROUND Pregnancy is a physiological stressful condition, which is accompanied by changes in cardiovascular parameters to fulfil the requirement of rapidly developing embryo and subsequent foetal growth. Serial evalua...

THE CHANGING CONCEPTS IN THE RETENTION OF MAXILLOFACIAL PROSTHESIS FROM PAST TO PRESENT- A REVIEW

BACKGROUND Defects in the maxillofacial region can be congenital or acquired, both always makes an individual depressed, hence requires rehabilitation. Maxillofacial prosthesis helps in replacing the congenitally missing...

FACTORS INFLUENCING SURGICAL OUTCOME OF MYRINGOPLASTY IN TUBOTYMPANIC TYPE OF CHRONIC OTITIS MEDIA

BACKGROUND Chronic otitis media is an inflammatory process of the mucoperiosteal lining of the middle ear space and mastoid. Infection of the middle ear has been a problem encountered in the human race, and is as old as...

TOPICAL APPLICATION OF INSULIN IN THE DIABETIC WOUND ULCER OF FOOT AND ITS COMPARISON WITH REGULAR NORMAL SALINE DRESSING

BACKGROUND Diabetic foot ulcers are inevitable in 15% of diabetic patients even if they follow the diet or control blood sugar level meticulously. The mainstay of treatment for diabetes related foot ulceration is a multi...

Download PDF file
  • EP ID EP550498
  • DOI 10.14260/jemds/2018/1227
  • Views 56
  • Downloads 0

How To Cite

Hiranmoy Deb, Sunny Kumar Mallick (2018). A COMPARATIVE STUDY BETWEEN INTRAOPERATIVE CLINICAL AND POSTOPERATIVE RADIOLOGICAL MEASUREMENT OF DISTANCE BETWEEN TIP OF GREATER TROCHANTER TO CENTER OF FEMORAL HEAD IN OPERATED CASES OF HIP HEMIARTHROPLASTY. Journal of Evolution of Medical and Dental Sciences, 7(52), 5543-5548. https://europub.co.uk/articles/-A-550498