A comparative study between manual vacuum aspiration and electrical suction in first trimester MTP

Journal Title: The New Indian Journal of OBGYN - Year 2018, Vol 4, Issue 2

Abstract

Objective: The objective of this study was to observe the efficacy of manual vacuum aspiration (MVA) and electrical suction/vacuum aspiration (EVA) for pregnancy termination and to compare the two techniques. Methodology: A prospective study of 200 cases of medical termination of unwanted pregnancy in first trimester was done by applying MVA and EVA at Gauhati Medical College and Hospital. Results: In this study majority of patients belonged to age group 26 - 30 years, Hindu religion and middle class. Maximum women were educated up to high school. Most of the patients had period of gestation between 6 to 8 weeks (44%) followed by up to 6 weeks (36%) in both the groups. Average blood loss in MVA was 33.9 ml and that of EVA 85.45 ml. Blood loss in both the groups increased with increasing gestational age. Average time taken was 11.77 and 16.55 minutes in MVA and EVA respectively. In terms of complication, no major complication was found except in 9% of cases MVA failed and had to be converted to EVA for complete evacuation. At postoperative period, mild bleeding (grade II) was seen in 22% cases mostly in patients of EVA group. As far as success rate is concerned, EVA got 100% while MVA got 91%. Conclusion: Both the techniques were found to be almost equally effective. Though blood loss is slightly lesser in MVA but success rate in term of complete evacuation is better in EVA.

Authors and Affiliations

Bijoy Kumar Dutta, Sudip Samanta

Keywords

Related Articles

Obstetric outcome in grand multipara – a Meghalaya experience

Objectives: This study was carried out to evaluate the obstetric and perinatal outcomes in grand multipara. Methods: A retrospective descriptive analytical study was carried out in the department of Obstetrics and Gyneco...

A prospective observational study to assess maternal and foetal outcome in underweight pregnant women

Objective: To assess the pregnancy outcome in underweight pregnant women and recommended preventable measures. Methodology: This prospective study is done between January to December 2014 in P.B.M Zanana Hospital, S.P M...

A bizarre self inflicted injury resulting in a 'Near-Miss' in a Gynaecological case

A 32 year old, para 3 woman presented in shock and drowsy condition with bleeding per vaginum. On gaining consciousness, the patient revealed that she had chopped off some part of her gentalia and flushed it. Her previou...

Bother and quality of life among symptomatic versus asymptomatic women with stage I – III pelvic organ prolapse

Objective: To compare the bother and quality of life in symptomatic and asymptomatic patients with stage I–III pelvic organ prolapse (POP). Methods: A descriptive study was conducted between August 2010 and October 2011,...

Screening for preeclampsia by urine albumin to creatinine ratio

Background: Proteinuria is a major component of preeclampsia. Urine protein measurement after 24 hour urine collection is the traditional standard method for the detection of proteinuria. It is time consuming. As an alte...

Download PDF file
  • EP ID EP453807
  • DOI 10.21276/obgyn.2018.4.2.13
  • Views 104
  • Downloads 0

How To Cite

Bijoy Kumar Dutta, Sudip Samanta (2018). A comparative study between manual vacuum aspiration and electrical suction in first trimester MTP. The New Indian Journal of OBGYN, 4(2), 154-157. https://europub.co.uk/articles/-A-453807