A COMPARATIVE STUDY OF ISOAMYL-2-CYANOACRYLATE (NOVOCRYL) WITH SUBCUTICULAR POLYAMIDE SUTURE FOR SURGICAL WOUND CLOSURE

Journal Title: Journal of Evidence Based Medicine and Healthcare - Year 2018, Vol 5, Issue 29

Abstract

BACKGROUND There are several concerns while selecting the mode of wound closure after surgery, whether major or minor procedure. One of the concerns is how fast and comfortable will be the recovery. A new technology is surgical adhesives, cyanoacrylates, 2- octyl cyanoacrylate is easier to use and provides a flexible, water resistant, sealed skin closure, 2 octyl cyanoacrylate provides a needle free method of wound closure, an important consideration because of blood borne viruses (e.g. HIV). The objectives of the study are- 1) To compare isoamyl-2-cyanoacrylate with subcuticular polyamide suture for skin closure in elective surgical procedures for the following characters. 2) To compare the cosmetic outcome. 3) To compare wound dehiscence & wound infection. MATERIALS AND METHODS This is a comparative study conducted on 50 patients in two groups at Bapuji Hospital and Chigateri General Hospital, Davangere in Department of General Surgery between 1st of January 2010 and 1st of July 2011. Cases undergoing clean elective surgical procedure were randomly selected and put into two groups. 1) Skin closure was done with 3-0 polyamide subcuticular sutures in one group. 2) Skin closure was achieved with 2–octyl cyanoacrylate in the other group. RESULTS Wound cosmesis assessment on day 7, the mean score for adhesive glue group was 5.84 which was slightly higher than the mean cosmesis score of 5.68 for subcuticular skin suturing (p=0.3). The cosmesis assessment at 1 month, the mean score for adhesive glue group was 5.9 and was 5.68 for subcuticular skin suturing group which was again not statistically significant (p=0.1). The mean wound ASEPSIS scores on day 3 for adhesive glue group was 0.28 and the same for subcuticular skin suturing group was 0.36 (p=0.7). The same score on day 5 for adhesive glue group was 0.12 and that of subcuticular skin suturing group was 0.28 (p=0.4). The results in both the groups were comparable in terms of wound infection rate. CONCLUSION Octyl cyanoacrylate provides an effective and reliable means of skin closure and yields similar cosmetic results as with subcuticular skin sutures. The incidence of infection and wound complications are comparable in both the groups. In addition, octyl cyanoacrylate provides certain practical advantages to the patients. The advice as to which method is used for closure of wound may come down to economics and operator preference.

Authors and Affiliations

Mahesh Dhotre, Chetan S. V

Keywords

Related Articles

FUNCTIONAL OUTCOME OF PHILOS PLATE FIXATION FOR PROXIMAL HUMERUS FRACTURES

INTRODUCTION Treating a proximal humerus fracture remained a challenging problem until proximal humeral internal locking system has been developed. Our study aims at evaluating the functional outcome of 30 consecutive pa...

A PROSPECTIVE STUDY OF NON-DESCENT VAGINAL HYSTERECTOMY

BACKGROUND The aim of the study is to assess the outcome in terms of safety, complication and feasibility of non-descent vaginal hysterectomy for benign gynaecological disease. MATERIALS AND METHODS A prospective study t...

COMPARISON OF POSTOP SIA IN MSICS WITH STRAIGHT INCISION VERSUS FROWN INCISION

BACKGROUND Surgically-Induced Astigmatism (SIA) is one of the commonest causes of poor postoperative vision even after uneventful cataract surgery. Recent advances have led to a newer concept of “refractive cataract surg...

SEARCH TO FIND OUT CAUSE OF COMPLICATIONS OF DIABETIC PATIENT WHO WENT ON VENTILATOR AFTER OPEN CHOLECYSTECTOMY

Diabetes is very common now-a-days. Incidences of diabetes are increasing day by day. If not managed properly it is a slow killing disease. Its detrimental effects on various organs are not revealed clinically during ini...

SINONASAL INFLAMMATORY POLYP PRESENTING LIKE A TUMOR: A CASE REPORT

Sinonasal mass with bony destruction, deviation of eye and opthalmoplegia raises the suspicion of tumor and requires extensive surgical approach. Benign masses and slow growing tumors tend to remodel the nasal vault and...

Download PDF file
  • EP ID EP569227
  • DOI 10.18410/jebmh/2018/452
  • Views 105
  • Downloads 0

How To Cite

Mahesh Dhotre, Chetan S. V (2018). A COMPARATIVE STUDY OF ISOAMYL-2-CYANOACRYLATE (NOVOCRYL) WITH SUBCUTICULAR POLYAMIDE SUTURE FOR SURGICAL WOUND CLOSURE. Journal of Evidence Based Medicine and Healthcare, 5(29), 2184-2192. https://europub.co.uk/articles/-A-569227