A Comparison of Transverse Section with Arc Shaped Turbulators as an Artificial Roughness on the Absorber Plate of a Solar Air Heater
Journal Title: International Journal of Science and Research (IJSR) - Year 2015, Vol 4, Issue 3
Abstract
Solar energy is most important renewable energy resource due to its quantitative abundance. The simplest and most efficient way to utilize solar energy is to convert it into thermal energy for heating applications. A solar collector is a device designed to absorb the incoming solar radiant energy converting into thermal energy at the absorbing surface and transforming this energy to a fluid flowing through the collector. Solar air heaters, because of their inherent simplicity, are cheap and most widely used collection devices. The primary disadvantage of solar air heaters is the need for handling relatively large volumes of air because of its low thermal capacity as working fluid. The thermal performance of a conventional solar air heater is poor because of relatively low heat transfer coefficient between absorber plate and the carrier fluid (air). Use of artificial roughness on the absorber plate has been found to be an effective method of enhancing heat transfer coefficient. In this present work an attempt is made to study the performance of solar air heater using wire geometry of arc shaped thin circular wires as a turbulators on the absorber plate. The investigation has covered a Reynolds number (Re) range of 3000-8000, relative roughness height (e/Dh) of 0.034, duct aspect ratio (W/B) is kept 5, the relative roughness pitch (p/e) used is 10,20,30 and 40. The heat transfer and friction factor values obtained are compared with those of smooth duct and Transverse wire geometry under similar flow conditions. Investigation shows the maximum enhancement of average Nusselt number is found to be 1.12 times for transverse wire geometry and 1.17 times for single arc wire geometry compared to that of smooth plate. The maximum enhancement of average friction factor is found to be 5.61 times for transvers wires geometry, 5.89 times for single arc wire geometry. The comparison of transverse and single arc shows that the Nusselt number , friction factor and efficiency index is highest for arc shaped roughness followed by transverse and least for smooth absorber plate.
Experimental Analysis on Performance of a Counter Flow Tray Type Cooling Tower
The main aim of this project is to increase the cooling rate by modifying the design i.e by replacing the fill material with the aluminum trays and reducing the height to provide an energy efficient. In this, use trays f...
Enhancing the Protection scheme for FACTS-Based Transmission Lines using a Data Mining Model
This review paper is based on the use of the thyristor control series compensator (TCSC) for the fault zone identification and protection of FACTS based transmission lines by using data mining model with the use of ensem...
RFID BASED ELECTRONIC PASSPORT
"We propose a system in which fingerprint verificationis donebyusing extraction of minutiae technique andthe systemthat automates thewhole process oftaking attendance 1,4,6], Manuallywhich is alaborious and troublesomew...
Severity of Diarrhea and Dehydration in Children Under 5 Years
The aim of this study was to assess the severity and type of dehydration in children with diarrhea who were admitted hospital. This is a retrospective study. A total of 345 cases of acute diarrhea mainly in children belo...
What Hinders Guidance and Counselling Effectiveness in Enhancing Discipline in High Schools in Murang’a County, Kenya
"Abstract The main purpose of this study was to assess the factors hindering the efficiency of guidance and counselling services in addressing school discipline in high schools in Kenya with specific focus on secondary s...