A Custom-made Pupillometer System for Characterizing Pupillary Light Response

Journal Title: TÜRK OFTALMOLOJİ DERGİSİ - Year 2018, Vol 48, Issue 4

Abstract

Objectives: This paper presents the design and construction of a viable pupillometer system and demonstrates its merits with extensive validation tests. Materials and Methods: A web camera was modified by removing its infrared filter and mounted on a chin rest. Light emitting diodes (LEDs) operating at infrared and visible spectra were integrated to provide background and light stimulus, respectively. The LEDs were controlled by a microprocessor board. Stimulation was presented using a periodic paradigm with variable period and duty cycle. Videos of both pupils were recorded at 30 frames/second and processed offline using software developed in-house. The overall system was validated with data gathered from individuals with healthy vision under different stimulation paradigms. Temporal variations in pupil size were determined and analyzed statistically. Results: The analysis revealed that the pupil sizes were accurately measured from the video frames provided that reflections from both infrared and visible lights remain outside the pupil. The system achieved moderate to excellent repeatability scores (87.8 and 86.8% for short 1 second and long 2 second pulses, respectively), which demonstrated its effectiveness and confirmed that it can be used reliably as a pupillometer. Conclusion: The proposed pupillometer system produces useful, quantitative data characterizing pupillary light response. However, further development and implementation are needed to potentially turn it into a low-cost alternative for other studies involving the autonomic nervous system, cognitive function, drug metabolism, pain response, psychology, fatigue, and sleep disorders.

Authors and Affiliations

Nefati Kıylıoğlu, Mahmut Alp Kılıç, Tolga Kocatürk, Seyhan Bahar Özkan, Mehmet Bilgen

Keywords

Related Articles

Yaşa Bağlı Maküla Dejenerasyonunda İntravitreal Anti-Vasküler Endotel Büyüme Faktörü Tedavisine Hastaların Uyumunu Etkileyen Faktörler

Amaç: Yaş tip yaşa bağlı maküla dejenerasyonunda (YBMD), intravitreal anti-vasküler endotel büyüme faktörü (VEGF) tedavisi uygulanan hastaların tedaviye uyumlarını etkileyen faktörlerin belirlenmesidir. Gereç ve Yöntem:...

Contrast Sensitivity in Microtropic and Anisometropic Eyes of Successfully Treated Amblyopes

Objectives: To assess and compare contrast sensitivity function in the previously amblyopic and non-amblyopic “normal” eyes of patients with microtropia and anisometropia who achieved 20/20 visual acuity after occlusion...

Bilateral Anterior Uveitis Revealing Relapsing Polychondritis

Relapsing polychondritis is a potentially lethal but rare systemic autoimmune disease. The major site of inflammation is the connective tissue, usually involving the ears, nose, larynx, tracheobronchial tree, and cardiov...

Atipik Hemolitik Üremik Sendrom İlişkili Purtscher Benzeri Retinopati

Yirmi beş yaşında kadın hasta üç gündür devam eden her iki gözde bulanık görme, baş ağrısı, baş dönmesi ve bayılma öyküsü ile kliniğimize başvurdu. Hastanın görme keskinliği her iki gözde 20/60 seviyesindeydi. Fundus mua...

Clinical Features and Surgical Results in Harada-Ito Surgery Patients

Symptomatic excyclotorsion is an important clinical problem, especially in acquired superior oblique muscle palsy. Excyclotorsion can disrupt the fusion and cause torsional diplopia. Harada-Ito surgery (HI) is a widely u...

Download PDF file
  • EP ID EP382164
  • DOI 10.4274/tjo.39049
  • Views 89
  • Downloads 0

How To Cite

Nefati Kıylıoğlu, Mahmut Alp Kılıç, Tolga Kocatürk, Seyhan Bahar Özkan, Mehmet Bilgen (2018). A Custom-made Pupillometer System for Characterizing Pupillary Light Response. TÜRK OFTALMOLOJİ DERGİSİ, 48(4), 185-189. https://europub.co.uk/articles/-A-382164