A Dosimetric Study on Indigenously Developed Heterogeneous Thorax Phantom for Radiation Dose Verification in Carcinoma Lung
Journal Title: Indian Journal of Cancer Education and Research - Year 2019, Vol 7, Issue 1
Abstract
Aim: To design and study the physical and radiological properties of Heterogeneous Thorax Phantom (HTP).Materials and Methods: The Computed Tomography (CT) images of thorax were imported on treatment planning system and analyzed for measuring the density of chest wall tissue, lung and soft tissue behind the lung. The mean and standard deviation of these different densities were noted and analyzed. A HTP with similar density distribution was made using slabs of SP34 and pinewood. A plan was made on actual patient’s CT scan and on HTP by putting 6 MV photon beam of 10x10 cm2 field size and source to surface distance of 100 cms perpendicular to the chest wall using anisotropic analytical algorithm with grid size 0.25 cm. Depths for isodose were measured in both the mediums. The CT scan of HTP was taken at three different interface regions. The doses were planned and measured at these three interface regions using ionization chamber. Measured and planned doses were compared and analyzed. Results: The mean density of the chest wall, lung and soft tissue were found to be 0.94, 0.28 and 0.98 gm/cc respectively on patient’s CT scan, while 0.99, 0.27 and 0.99 gm/cc respectively in HTP. Variation in planned dose and measured dose on HTP at 6 cm, 10 cm and 18 cm depths were found to be 0.47%, 0.81% and 2.4%. Conclusion: Phantom mimicking thorax site along with advanced third generation Monte Carlo based algorithms which are based on biological dose calculation should be used for more accurate dose calculation.
Authors and Affiliations
Virendra Bhandari
Hypoxia Inducible Factor-1 (HIF-1) and Cancer Progression: A Comprehensive Review
Hypoxia is characterized as a decrease oxygen levels in tissue, represents a fundamental pathophysiological condition in the microenvironment of solid tumors. The key component of hypoxia sensing in the cell is the hypox...
Isolation of MTB Strains and Determining the Antibiotic Susceptibility Pattern via Bactec 320 from the Females of Child Bearing Age
Background: The BACTEC MGIT 320 is a new, lower-capacity instrument for liquid culture developed for the growth and detection of M. tuberculosis and antimicrobial susceptibility testing. MGIT has an improved speed and se...
Drug Utilization Review of Anticancer Drugs in Medical Oncology Department of a Tertiary Care Teaching Hospital
The present study aimed to analyze the drug utilization pattern of anticancer drugs in medical oncology department of a tertiary care teaching hospital, Tamilnadu. Each prescription in the department of medical oncology...
Comparision of Carcinoma Cervix Treated with Conventional vs Intensity Modulated Radiotherapy with Concurrent Chemotherapy
Introduction: Cervical cancer is the fourth most common cancer in women, and the seventh overall, Use of IMRT in pelvic malignancies has shown reduced radiation exposure to adjacent bowel and bladder. IMRT is superior to...
Sebaceous Gland Carcinoma of Upper Eyelid with Parotid Metastasis: A Case Report
Sebaceous gland carcinoma is a rare malignancy which usually arises from periocular region. It accounts of 1–5.5% eyelid malignancies and represents third most common eyelid malignancy. It mostly occurs in elderly women...