A Fault Detection and Protection Scheme for A 200 MVA Transformer Using Fuzzy Logic

Abstract

The paper elucidates a fault detection and protection scheme for a 200MVA transformer using Fuzzy logic. Fuzzy logic (FL) tool box in MATLAB/ SIMULINK software was utilized in the simulation system that diagnosed transformer faults and also monitors its operating conditions. Current and rate of change of current with time have been identified as the input variables, duly represented in the programme as “Error” and “Error-Dot”. These variables have their universe of discourse from -1.5 to 1.5 and from -10 to 10 respectively. Fuzzy logic sensor is designed to monitor the current (i) conditions of the transformer at both ambient and full load. The results from the research show that whenever the output response is zero the current in transformer is normal. This is obtained when input values of [0] and [0] are injected into the system to produce a response of “6e-017” which is approximately zero. Whereas if the output response is greater than zero it implies that the transformer current is rising beyond normal and protection scheme should be alerted. This condition is achieved when input values of [-1.5] and [5] are used on the system to give a response of “+5”. However, if the response is less than zero then the transformer current is below normal, hence the protection scheme should be alerted. To investigate this, input values of [1.5] and [-5] gives a response of “-5”.

Authors and Affiliations

S. O. Okolo, T. C. Madueme

Keywords

Related Articles

Electrical Energy Harvesting From Mechanical Pressure of Vehicles Using Piezoelectric Generators

The paper is intended to forecast the present condition of energy utilization and the usage of the resources in the generation process. According to International Energy Agency’s New Policies Scenario demand of global el...

GA Based Controller for Autonomous Wind-DG Micro grid

A single renewable source of energy when integrated with other sources of energy it is termed as hybrid system. In this paper an active power control strategy has been developed such that when the wind alone is not able...

Portable Smart Phone Charger Using Human Mechanical Energy by Gear Train with Hand Crank

Mobile phone is our means to remain connected. While the phones have progressively got more powerful processors and large touch screen interfaces, their power requirement has increased correspondingly. Unfortunately, bat...

A Comparative Study of Different Traveling Wave Fault Location Techniques

Power transmission lines transfer a huge amount of electricity from generation stations to distribution centers. The flow of the large currents causes faults along transmission lines, leading to extended power outages an...

Circular Polarized Carbon-NanotubePatch Antenna embedded in Superstrates Anisotropic Media

The current distribution on surface of the Patch Antenna is radiating in the presence of the Superstrates layered anisotropic medium. The electric and magnetic field in the upper half-space are formulated using Dyadic Gr...

Download PDF file
  • EP ID EP388684
  • DOI 10.9790/1676-1302011623.
  • Views 128
  • Downloads 0

How To Cite

S. O. Okolo, T. C. Madueme (2018). A Fault Detection and Protection Scheme for A 200 MVA Transformer Using Fuzzy Logic. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(2), 16-23. https://europub.co.uk/articles/-A-388684