A Highly Sensitive Electrochemical Glucose Sensor By Nickel-Epoxy Electrode With Non-Enzymatic Sensor
Journal Title: Eksakta: Jurnal Ilmu-Ilmu MIPA - Year 2016, Vol 16, Issue 1
Abstract
The preparation of new sensor for glucose was based on the fact that glucose can be determined by non-enzymatic glucose oxidase. The Ni metals (99.98% purity, 0.5 mm thick, Aldrich Chemical Company) was used to prepare Ni-Epoxy electrode. The Ni-epoxy electrodes were prepared in square cut of 1 cm and 1 mm by length and wide respectively. The Ni metal electrodes were connected to silver wire with silver conducting paint prior covered with epoxy gum. The prepared of nickel-epoxy modified electrode showed outstanding electro catalytic activity toward the oxidation of glucose in alkaline solution. The result from this research are correlation of determination using Nickel-Epoxy electrode for electroanalysis of glucose in NaOH was R2= 0.9984. LOQ, LOD and recovery of the = Nickel-Epoxy electrode towards glucose were found to be 4.4 μM, 1.48 μM and 98.19%, respectively. The Nickel-Epoxy wire based electrochemical glucose sensor demonstrates good sensitivity, wide linear range, outstanding detection limit, attractive selectivity, good reproducibility, high stability as well as prominent feasibility use of non-enzymatic sensor for monitoring glucose in human urine owing to its advantages of low cost, simple preparation and excellent properties for glucose detection
Extraction and Chemical Compounds Identification of Red Rice Bran Oil Using Gas Chromatography - Mass Spectrometry (GC-MS) Method
The objectives of the study are to obtain optimum yield of extraction red rice bran oil, to determine the physico-chemical characteristics, and componen coumpounds. Data was analyzed using Nir Parametric Statistics by...
Air Pollution Simulation From Cirebon Power Plant Activity
Air pollution modelling from Cirebon power plant activity has been performed by using gaussian plume model. Gaussian plume equation was applied to predict the distribution and concentration of pollutant gases in the air....
Comparison the Error Rate of Autoregressive Distributed Lag (ARDL) and Vector Autoregressive (VAR) (Case study: Forecast of Export Quantities in DIY)
Forecasting is estimating the size or number of something in the future. Regression model that enters current independent variable value, and lagged value is called distributed-lag model, if it enters one or more lagged...
Formulation and Evaluation of Kaptopril Tablets Using Threaded Amylum Tubes and HPMC as Fillers and Binders of the Direct Method
Indonesia is a tropical country which has many potential plants as excipients, like starches and tubers. Amylum of taro tuber (Colocasia esculenta) has the potential to be developed into excipient but its use is limited....
Kinetics Study Of Au(Iii) Adsorption On Gallic Acid Intercalated Mg/Al-Hydrotalcite
Kinetics study of Au(III) adsorption on gallic acidintercalated Mg/Al-hydrotalcite (Mg/Al-HT) is conducted by means of interacting between the Au(III) solution with AuCl4 -species with GA intercalated Mg/Al-HT synthesize...