A METHOD FOR DETERMINING LOCATION OF VOLTAGE FLUCTUATIONS SOURCE IN ELECTRIC GRID

Abstract

Purpose. The purpose of work is development of a method of definition of the location of a source of fluctuations of voltage. Methodology. The reasons of emergence of fluctuations of voltage at an arrangement of a source both in power lines, and in the consumer's networks, are connected with changes of consumption and active and reactive capacities. As criterion for definition of the location of a source of fluctuations of voltage we choose change of size of the active power received by reception substation on equivalent communication with system. The source of fluctuations of voltage is external for the consumer if emergence of fluctuations of voltage leads to the coordinated changes of tension and consumed in the area of active power that corresponds to a condition of the positive regulating effect of active loading on voltage (1). The source of fluctuations of voltage is internal for the consumer if emergence of fluctuations of voltage leads to counter changes of tension and consumed in the area of active power that resembles a condition of the negative regulating effect of active loading on voltage superficially (6). Results. The method of definition of the location of a source of fluctuations of voltage in an electric network which, works by the principle of an assessment of correlation of change of power and tension in a power supply network is developed. The method allows to consider shift between extrema of curves of change of voltage of U(t) and power of Pload(t). Originality. The method of definition of an arrangement of a source of fluctuations of voltage is developed. Practical value. The answer to this question where the source of fluctuations of voltage (in the territory of the consumer is located or in an external network) confirmed with the determined calculation, can form a basis of the expert opinion for the solution of legal disputes at an assessment of the damages caused by poor quality of electric energy.

Authors and Affiliations

G. A. Senderovich, A. V. Diachenko

Keywords

Related Articles

DYNAMIC REGIMES OF ASYNCHRONOUS MOTORS WITH CONCATENATED CAPACITORS

Purpose. Development of mathematical model for calculation of starting modes of asynchronous motor connected in series with capacitors. Method. Mathematical modeling of dynamic modes of asynchronous motors with lateral c...

INVESTIGATION AND CALCULATION OF VALLEYS OF OUTGOING FROM SUBSTATION GROUNDING CONDUCTORS FOR SHORT-CIRCUIT IN SINGLE-PHASE SHORT OF ELECTRICAL GRID

Introduction. Earthing device electrical substation in modern conditions must meet both the requirements of electrical safety of people and animals, as well as electromagnetic compatibility requirements established her e...

COMPARATIVE ANALYSIS OF ACTIVE POWER LOSSES OF INDUCTION MOTORS WITH CYLINDRICAL AND AXIAL AIR GAPS

Purpose. To find the analytical expressions of determining the optimum geometric dimensions by criteria of the losses minimum of axial field squirrel-cage induction motors and to compare traditional and axial field motor...

MODELING PARAMETERS OF ARC OF ELECTRIC ARC FURNACE

Purpose. The aim is to build a mathematical model of the electric arc of arc furnace (EAF). The model should clearly show the relationship between the main parameters of the arc. These parameters determine the properties...

EFFICIENCY EVALUATION TECHNIQUE OF THE SEMICONDUCTOR DC-DC CONVERTER APPLICATION IN THE POWER-SUPPLY SYSTEM

Purpose. To specify efficiency evaluation of the DС-DC power semiconductor converter application in the power-supply system. Methodology. We have chosen application version of converter and then used the statistical mode...

Download PDF file
  • EP ID EP297978
  • DOI 10.20998/2074-272X.2016.3.09
  • Views 85
  • Downloads 0

How To Cite

G. A. Senderovich, A. V. Diachenko (2016). A METHOD FOR DETERMINING LOCATION OF VOLTAGE FLUCTUATIONS SOURCE IN ELECTRIC GRID. Електротехніка і Електромеханіка, 0(3), 58-61. https://europub.co.uk/articles/-A-297978