A method for identifying pleural lines in B-mode ultrasound images
Journal Title: Progress in Medical Devices - Year 2023, Vol 1, Issue 2
Abstract
In ultrasound imaging, the pleura is visualized as echo reflection formed by the echoes of the interface between the pleura and the lung surface. Three major signs of pleura determines whether the patient has pneumothorax. In this paper, we propose a method to identify pleural line for the diagnosis of pneumothorax. Firstly, the gray threshold of ultrasonic image is properly classified by pre-experiment. Secondly, possible pleural line regions are identified based on threshold classification. Thirdly, the region of pleural line is identified based on the known characteristics of pleural line. The last step is to consider whether it is necessary to modify the threshold to accurately identify the pleural line region. Moreover, we tested 890 ultrasound samples, which included three categories: lung sliding, lung point, and lung sliding disappearance. Each category of samples was divided into two subsets, typical and atypical. The average identification rate reached 90.45%. According to the test results, the advantages and disadvantages of the proposed method as well as the further improvement direction were analyzed. This method for identifying pleural line can serve as the groundwork for developing automatic algorithm for diagnosing pneumothorax.
Authors and Affiliations
Tingting Zhou, Haozhe Zhuang, Shiju Yan, Erze Xie, Yibo Ma, Tao Zhang, Tianxiang Yu, Shuang Deng
Approaches to enhance patient tolerance during gastrointestinal endoscopic examination: A literature review
In recent years, the importance of endoscopic procedures has risen significantly in response to the escalating prevalence of digestive system diseases. The gastroenteroscopic technique has undergone several iteration and...
Review of methods for detecting electrode-tissue contact status during atrial fibrillation ablation
Atrial fibrillation is a common cardiac arrhythmia with an annually increasing global prevalence. Ablation of atrial fibrillation is a minimally invasive procedure that treats atrial fibrillation by using a catheter to...
Review of gait prediction of lower extremity exoskeleton robot
In recent years, gait prediction has gradually become a cutting-edge research direction in the fields of biomechanics and artificial intelligence. Gait prediction technology, which analyzes an individual’s walking patter...
Optimization design and performance study of magnesium alloy vascular clamp
Purpose: This study investigates the effects of varying inner diameter of a vascular clamp made from an Mg–Nd–Zn–Zr alloy on its functional performance. The primary objectives are to optimize the clamp’s structure, asses...
Progress on Microfluidic Blood Cell Counting Techniques
Accurately and efficiently detecting the quantity of blood cells is crucial in routine blood examination, as abnormal high or low numbers of blood cells are associated with the occurrence of various disorders. Due to inh...