A Method for Improving Renogram Production and Detection of Renal Pelvis using Mathematical Morphology on Scintigraphic Images

Journal Title: Engineering, Technology & Applied Science Research - Year 2012, Vol 2, Issue 4

Abstract

Dynamic renal scintigraphy is a well-established imaging technique in nuclear medicine, used to detail both the organ's anatomy and function. However, the quality of the produced scintigrams provides an often unreliable diagnostic tool because of a rather bad signal-to-noise ratio and the fact that in certain occasions the regions of interest are too concentrated making it difficult for physician evaluation. The goal of this paper is to achieve a more accurate production of the renal activity graph, by avoiding the inclusion of image artifacts in the detection process. This is achieved by treating pixels as points in a two-dimensional Euclidean space, and exploiting set-theoretic properties and morphological operators. The evaluation of the method in a number of real patient’s scintigrams obtained in a depth of 5 years, showed that, in the majority of the cases, it is feasible to produce a more accurate renogram, for both kidneys and the renal pelvis region, that was helpful for the interpretation of the findings

Authors and Affiliations

S. Xefteris, K. Tserpes, T. Varvarigou

Keywords

Related Articles

Environmental Risk Assessment and Management in Oil Platform Construction Phase Activities: A Case Study

The construction phase is one of the very risky stages engaged in oilfields, which usually involves minor to severe human, financial, and environmental damages. It includes a major part of lost working times, and in rece...

Effects of Climate Change on Mountain Waters: A Case Study of European Alps

The Alps play a vital role in the water supply of the region through the rivers Danube, Rhine, Po and Rhone while they are crucial to the ecosystem. Over the past two centuries, we witnessed the temperature to increase b...

Framework for Operational Performance Measurements in Small and Medium Scale Industries Using Discrete Event Simulation Approach

Globally, production systems must cope with limitations arising from variabilities and complexities due to globalization and technological advancements. To survive in spite of these challenges, critical process measures...

Optimization of Emulsion Liquid Membrane for Lead Separation from Aqueous Solutions

This study focuses on evaluating the process parameters and their effects on extraction of lead as well as emulsion breaking. The Signal / Noise ratios have been used to study the performance characteristics. Six paramet...

Application of Fuzzy Expert Systems to Manage the Projects Time in Iranian Gas Refineries

The National Iranian Gas Company (NIGC) is one of the top ten gas companies in the gas industry in the Middle East and is comprised of 7 gas refineries. So this company needs to apply the most optimum time management met...

Download PDF file
  • EP ID EP88706
  • DOI -
  • Views 335
  • Downloads 0

How To Cite

S. Xefteris, K. Tserpes, T. Varvarigou (2012). A Method for Improving Renogram Production and Detection of Renal Pelvis using Mathematical Morphology on Scintigraphic Images. Engineering, Technology & Applied Science Research, 2(4), -. https://europub.co.uk/articles/-A-88706