A New Calibration Method for SAR Analog-to-Digital Converters Based on All Digital Dithering

Journal Title: Journal of Information Systems and Telecommunication - Year 2017, Vol 5, Issue 1

Abstract

In this paper a new digital background calibration method for successive approximation register analog to digital converters is presented. For developing, a perturbation signal is added and also digital offset is injected. One of the main advantages of this work is that it is completely digitally and eliminates the nonlinear errors between analog capacitor and array capacitors due to converter’s capacitors mismatch error by correcting the relative weights. Performing of this digital dithering method does not require extra capacitors or double independent converters and it will eliminate mismatches caused by these added elements. Also, No extra calibration overhead for complicated mathematical calculation is needed. It unlike split calibration, does not need two independent converters for production of two specified paths and it just have one capacitor array which makes it possible with simple architecture. Furthermore, to improve DNL and INL and correct the missing code error, sub radix-2 is used in the converter structure. Proposed calibration method is implemented by a 10 bit, 1.87-radix SAR converter. Simulation results with MATLAB software show great improvement in static and dynamic characteristics in applied analog to digital converter after calibration. So, it can be used in calibration of successive approximation register analog to digital converters.

Authors and Affiliations

Ebrahim Farshidi, Shabnam Rahbar

Keywords

Related Articles

Active Steganalysis of Transform Domain Steganography Based on Sparse Component Analysis

This paper presents a new active steganalysis method to break the transform domain steganography. Most of steganalysis techniques focus on detecting the presence or absence of a secret message in a cover (passive stegana...

A New Method for Detecting the Number of Coherent Sources in the Presence of Colored Noise

In this paper, a new method for determining the number of coherent/correlated signals in the presence of colored noise is proposed which is based on the Eigen Increment Threshold (EIT) method. First, we present a new app...

Design of Fall Detection System: A Dynamic Pattern Approach with Fuzzy Logic and Motion Estimation

Every year thousands of the elderly suffer serious damages such as articular fractures, broken bones and even death due to their fall. Automatic detection of the abnormal walking in people, especially such accidents as t...

SRR shape dual band CPW-fed monopole antenna for WiMAX / WLAN applications

CPW structure is became common structure for UWB and multi band antenna design and SRR structure is well-known kind of metamaterial that has been used in antenna and filter design for multi band application. In this pape...

Ten Steps for Software Quality Rating Considering ISO/IEC

In software rating area, it is necessary to apply a measurement reference model to evaluate the quality of software. The standard 25030 is an example of an evaluation system which is based on stakeholders' requirements....

Download PDF file
  • EP ID EP183816
  • DOI -
  • Views 163
  • Downloads 0

How To Cite

Ebrahim Farshidi, Shabnam Rahbar (2017). A New Calibration Method for SAR Analog-to-Digital Converters Based on All Digital Dithering. Journal of Information Systems and Telecommunication, 5(1), 1-6. https://europub.co.uk/articles/-A-183816