A New Method of Reference Signal Generation Applied To UPQC-PHEV For Grid Integration of WECS-SCIG

Abstract

In this paper a new reference signal generation control technique is proposed for integration of Unified Power Quality Conditioner (UPQC) with Plug-in Hybrid Electric Vehicle (PHEV) for overcoming voltage sag and other voltage fault conditions on wind farms which is connected to grid. The interaction of wind generators and grid causes increased short circuit current which leads to instability during fault conditions. The new control technique which generate reference signals for series active power filter (Series APF) and shunt active power filter (Shunt APF) of UPQC by using PHEV as an Energy Storage System (ESS) which will take care of all types of voltage faults occurred in the system and provide energy storage to DC link between Series APF and Shunt APF parts of UPQC. The control scheme proposed also maintains transaction of active and reactive power of Wind Energy Conversion System based on Squirrel Cage Induction Generators (WECS-SCIG) and grid. The fuzzy logic provides fast and dynamic response to clear faults occurred in the system.

Authors and Affiliations

Girish B M, Prof. Anguraja R

Keywords

Related Articles

Novel Design and Implementation of Graph Mining for Big Data Network Analysis

The Research entitled Application of Graph Theory to Big Networks for Big Data” is an innovative idea having novel design and exemplar implementations on various case studies. Graph Mining strategies can be applied for B...

Evaluation Of Bituminous Mix Parameters With Addition Of Plastic Waste

Road construction is the main integral part of the developing countries. The conventional method has been proven perfect for the road construction but now, time has come where there is a need of enhancement of properties...

Cost Analysis OF 100 KW GRID Connected Solar Plant AT YIT – A Case Study

Whole of the world is facing the problem of energy crisis due to the increasing in load demand and limited amount of fossil fuels available on the earth. To overcome this problem, alternative energy resources are being u...

Does a Hybrid Approach of Agile and Plan-Driven Methods Work Better for IT System Development Projects?

With a focus on large-scale IT system development projects in diverse enterprises, this research suggests that a hybrid approach combining agile and plan-driven management methods should fit in a wider context of specifi...

Power Quality Improvement using Passive shunt filters, TCR and TSC combination

In this thesis Power Quality Improvement is examined using Passive shunt filter, TCR and TSC combination. Today’s electric power systems are connected to many non-linear loads. The characteristics of these non-linear loa...

Download PDF file
  • EP ID EP390106
  • DOI 10.9790/9622- 0702034148.
  • Views 178
  • Downloads 0

How To Cite

Girish B M, Prof. Anguraja R (2017). A New Method of Reference Signal Generation Applied To UPQC-PHEV For Grid Integration of WECS-SCIG. International Journal of engineering Research and Applications, 7(2), 41-48. https://europub.co.uk/articles/-A-390106