A New Under-Frequency Load Shedding Method Using the Voltage Electrical Distance and Artificial Neural Networks

Abstract

This paper proposes a method for determining location to shed the load in order to recover the frequency back to the allowable range. Prioritize distribution of the load shedding at load bus positions based on the voltage electrical distance between the outage generator and the loads. The nearer the load bus from the outage generator is, the sooner the load bus will shed and vice versa. Finally, by selecting the rate of change of generation active power, rate of change of active power of load, rate of change of frequency, rate of change of branches active power and rate of change of voltage in the system as the input to an Artificial Neural Network, the generators outage, the load shedding bus are determined in a short period of time to maintain the stability of the system. With this technique, a large amount of load shedding could be avoided, hence, saved from economic losses. The effectiveness of the proposed method tested on the IEEE 39 Bus New England has demonstrated the effectiveness of this method.

Authors and Affiliations

Keywords

Related Articles

Adoption of Mobile Money Services among University Students in Tanzania

The focus of the study was to assess factors influencing adoption of mobile money services among university students in Tanzania. The study adopted a quantitative approach where questionnaire was used to collect data fro...

Intelligent Healthcare Monitoring in IoT

The developing of IoT-based health care systems must ensure and increase the safety of the patients, their quality of life and other health care activities. We may not be aware of the health condition of the patient duri...

Appraisal of the Choice of College among Management and Business Technology Freshman Students

This paper aimed to investigate who influenced the 211 freshman students from the College of Management and Business Technology (CMBT) to take their course.Their influencers’ reasons for choosing the course and selecting...

Anti-Theft Protection of Vehicle by GSM & GPS with Fingerprint Verification

This paper focuses on preventing car theft using microcontrollers and GSM modules. We are generating the results with better accuracy and proficiency. It can be helpful to those people who want better and more advanced s...

Factors that Impede the Formation of Self-Directed work teams in Mexican Organizations

The most efficient work teams are self-directed work teams (SDWTs). In the United States, seventy-five percent of medium and large companies use SDWTs. The United States has a higher economic performance than Mexico. In...

Download PDF file
  • EP ID EP507530
  • DOI 10.22161/ijaems.5.3.3
  • Views 103
  • Downloads 0

How To Cite

(2019). A New Under-Frequency Load Shedding Method Using the Voltage Electrical Distance and Artificial Neural Networks. International Journal of Advanced engineering, Management and Science, 5(3), -. https://europub.co.uk/articles/-A-507530