A novel volumetric analysis using cad/cam scanners in gingival recession treatment

Journal Title: Medical Science and Discovery - Year 2017, Vol 4, Issue 10

Abstract

Objective: In this study, randomized clinical trial (RCT), the aim was to compare clinical periodontal data of subepithelial connective tissue graft (SCTG) group and SCGT+enamel matrix derivatives (EMD) group in terms of gained gingiva volume (GGV) and gained gingiva surface area (GGSA) by scanners of computer-aided design/computer-aided manufacturing (CAD/CAM) devices. Material and Methods: In this study, a total of 35 Miller class I-II gingival recession defects were involved (n=17 in SCTG group, n=18 in SCTG+EMD group). In addition to, periodontal clinical parameters, and  three dimensional (3D) images were recorded by using CAD/CAM system before the treatment, at the 1st month and the 6th months after the treatment. The images were superimposed by using softwares and GGV, and GGSA were calculated. Results: There was no significant difference in terms of GGV and GGSA values at the 1st month and 6th months between SCTG+EMD and SCTG groups. Similarly, there was no  significant difference in periodontal clinical parameters between groups. Conclusion: Images obtained from CAD/CAM system can be easily used in calculating GGV and GGSA data after the gingival recession treatment and in determining of the success of administered treatment. It is expected that the evaluation of the success of many therapeutic approaches for periodontal treatment will be carried out by using CAD/CAM system in the future.

Authors and Affiliations

Hacer Sahin Aydinyurt, Abdullah Seckin Ertugrul

Keywords

Related Articles

Thoracoabdominal asynchrony correlates with peripheral vascular resistance changes in a cohort of obese children.

Objective: The purpose of this study was to assess the relationship between the thoracoabdominal asynchrony (phase angle), as an index of inspiratory airflow resistance, pulse transit time arousal index (PTT A...

A possible alternate pathway for intravascular thrombosis - Investigation of the circumstantial evidence by microfluidics

In light of the literature, in this hypothesis, we aimed to settle up an experimental procedure and possible mechanism for bacteremia induced disseminated intravascular coagulation via QA. Bacteremia resulting in sepsis...

Stereotactic radiotherapy for patients with metallic implants on vertebral body: A dosimetric comparison

Objective: Metallic implants have impacts on dose distribution of radiotherapy. Our purpose is evaluating impact of metallic implants with different dose calculation algorithms on dose distribution. Mater...

Open laryngeal fracture: A case report and review of the literature

Laryngeal fracture is a rare and life threatening entity which is caused by blunt or penetrating neck trauma. Majority of laryngeal fractures are closed type and caused by blunt neck trauma. They frequently left underdia...

Rat brain synaptosomes: In vitro neuroprotective effects of betaine against fluoride toxicity

Objective: Fluoride increases the production of reactive oxygen and nitrogen derivatives, causing oxidative stress and cellular damage. Betaine, an antioxidant and an important methyl donor, has been reported...

Download PDF file
  • EP ID EP520735
  • DOI 10.17546/msd.341826
  • Views 57
  • Downloads 0

How To Cite

Hacer Sahin Aydinyurt, Abdullah Seckin Ertugrul (2017). A novel volumetric analysis using cad/cam scanners in gingival recession treatment. Medical Science and Discovery, 4(10), 72-79. https://europub.co.uk/articles/-A-520735