A Prospective controlled comparative study of haemodynamic responses, intubating conditions to laryngoscopy and tracheal intubation by using Macintosh vs. Mc Coy blade laryngoscope
Journal Title: MRIMS Journal of Health Sciences - Year 2018, Vol 6, Issue 1
Abstract
Abstract: Background: The invention of McCoy blade in the early 1990s is a modification of the Macintosh blade with a hinged tip. The McCoy blade reduces the amount of force applied during laryngoscopy and endotracheal intubation, thus the increased reflex haemodynamic changes in response to tracheal intubation becomes less significant. Objective: To determine the advantages of McCoy blade laryngoscope in obtunding the pressor response, better glottic visualization and ease of intubation during laryngoscopy and endotracheal intubation as compared to Macintosh blade laryngoscope. Methods: The present study was done on 60 adult patients of ASA I and II, between the age group of 20 to 50 years. We observed the haemodynamic changes, glottic view and ease of intubation by using either Macintosh or McCoy blade laryngoscope during general anesthesia at laryngoscopy and endotracheal intubation. The changes in HR, SBP, DBP, and MAP were recorded before induction, at laryngoscopy and intubation and at 1 min, 3 min and 5 min after tracheal intubation. Glottic view obtained on laryngoscope was compared as per Cormack and Lehene grading. Tracheal intubation grading was also compared between the groups. Complications during the procedure like arrhythmias, injury, and bleeding were noted. Results: In our study, a significant haemodynamic changes were observed in both the groups following laryngoscopy and endotracheal intubation. The rise in HR, SBP, DBP and MAP were more significant with Macintosh blade laryngoscope, where as better visualization of the glottis, ease of intubation and less haemodynamic changes were noted with McCoy blade laryngoscope. Conclusion: McCoy blade laryngoscope produces significantly less marked haemodynamic changes, better glottic view and ease of intubation as compared to Macintosh blade laryngoscope during laryngoscopy and tracheal intubation. Key words: Macintosh blade, McCoy blade, endotracheal intubation, Haemodynamic response, glottic view
Authors and Affiliations
Sarada Devi V, Lakshmi Narasimham M, Manjula VR, Saroj P, Surender P
Variation in shapes of coronoid process in human mandibles
Background: Various shapes of coronoid process have been described, they are triangular, rounded and hook shape. The shape and size of the coronoid process is influenced by dietary habit, genetic constitution, hormones a...
Alteration in different lipoprotein fractions in chronic renal failure patients
Background: Chronic renal failure, which is an inevitable terminal pathway of any chronic renal parenchymal disease, is more known for its morbidity than for its mortality. Objective: To note the alteration in different...
Attenuation of hemodynamic response to laryngoscopy and intubation-The Effect of Diltiazem, A randomized controlled study
Abstract: Background: Direct laryngoscopy and tracheal intubation following induction of anesthesia is almost always associated with hemodynamic changes due to reflex sympatho-adrenal activity which may result in hypert...
A study of effect of iron on hematological status in iron deficiency anemic children
Background: Iron Deficiency is the most widely prevalent nutritional disorder affecting the world population today. Anaemia has been described as a major health problem in the developing countries. Iron Deficiency Anaemi...
Effect of Drotaverine administration on cervical dilatation in uncomplicated deliveries
Background: Prolonged labour can lead to increased maternal and neonatal mortality and morbidities. Active management of labour versus physiological, expectant management has shown to decrease the occurrence of prolonged...