A Prospective controlled comparative study of haemodynamic responses, intubating conditions to laryngoscopy and tracheal intubation by using Macintosh vs. Mc Coy blade laryngoscope

Journal Title: MRIMS Journal of Health Sciences - Year 2018, Vol 6, Issue 1

Abstract

Abstract: Background: The invention of McCoy blade in the early 1990s is a modification of the Macintosh blade with a hinged tip. The McCoy blade reduces the amount of force applied during laryngoscopy and endotracheal intubation, thus the increased reflex haemodynamic changes in response to tracheal intubation becomes less significant. Objective: To determine the advantages of McCoy blade laryngoscope in obtunding the pressor response, better glottic visualization and ease of intubation during laryngoscopy and endotracheal intubation as compared to Macintosh blade laryngoscope. Methods: The present study was done on 60 adult patients of ASA I and II, between the age group of 20 to 50 years. We observed the haemodynamic changes, glottic view and ease of intubation by using either Macintosh or McCoy blade laryngoscope during general anesthesia at laryngoscopy and endotracheal intubation. The changes in HR, SBP, DBP, and MAP were recorded before induction, at laryngoscopy and intubation and at 1 min, 3 min and 5 min after tracheal intubation. Glottic view obtained on laryngoscope was compared as per Cormack and Lehene grading. Tracheal intubation grading was also compared between the groups. Complications during the procedure like arrhythmias, injury, and bleeding were noted. Results: In our study, a significant haemodynamic changes were observed in both the groups following laryngoscopy and endotracheal intubation. The rise in HR, SBP, DBP and MAP were more significant with Macintosh blade laryngoscope, where as better visualization of the glottis, ease of intubation and less haemodynamic changes were noted with McCoy blade laryngoscope. Conclusion: McCoy blade laryngoscope produces significantly less marked haemodynamic changes, better glottic view and ease of intubation as compared to Macintosh blade laryngoscope during laryngoscopy and tracheal intubation. Key words: Macintosh blade, McCoy blade, endotracheal intubation, Haemodynamic response, glottic view

Authors and Affiliations

Sarada Devi V, Lakshmi Narasimham M, Manjula VR, Saroj P, Surender P

Keywords

Related Articles

A retrospective epidemiological study of human rabies cases admitted in Sir Ronald Ross Institute of Tropical and Communicable Diseases

Rabies is one of the deadliest diseases known to man; it remains a neglected zoonotic disease throughout the developing countries. Rabies is an acute condition, 100% fatal and it is transmitted to humans through animal...

Assessment of erythrocyte SOD activity in different stages of Essential Hypertension patients

Oxidative stress has been found to be associated with most of the diseases. In the past several years, much interest has arisen over the involvement of free radical metabolism in the disturbance in endothelial or intimal...

A prospective study of cervical spinal injuries

Abstract: Cervical spinal injuries are potentially the most devastating injuries. This study conducted in Central Morgue, Department of Forensic Medicine and Toxicology, S.C.B. Medical College & Hospital, Cuttack, India...

Role and efficacy of rigid sinus video endoscopes in cases with failed intubation for micro laryngeal surgeries

Successful intubation and securing the airway is a prerequisite for microlaryngeal surgeries. Failed intubation with routine intubation techniques, the unsuitability of supraglottic devices and the unavailability of flex...

Spontaneous neonatal pneumomediastinum: A Case Report

Radiolucency in mediastinum may be caused by congenital cystic mass, pneumomediastinum or pneumopericardium. Most cases of pneumomediastinum occur in preterm newborns with surfactant deficiency receiving treatment with p...

Download PDF file
  • EP ID EP474714
  • DOI -
  • Views 122
  • Downloads 0

How To Cite

Sarada Devi V, Lakshmi Narasimham M, Manjula VR, Saroj P, Surender P (2018). A Prospective controlled comparative study of haemodynamic responses, intubating conditions to laryngoscopy and tracheal intubation by using Macintosh vs. Mc Coy blade laryngoscope. MRIMS Journal of Health Sciences, 6(1), 1-5. https://europub.co.uk/articles/-A-474714