A REVIEW OF EXPERIMENTAL STUDY AND CFD BASED SIMULATION OF CLOSED LOOP PULSATING HEAT PIPE

Journal Title: International journal of research -GRANTHAALAYAH - Year 2016, Vol 4, Issue 7

Abstract

Closed loop pulsating heat pipe is very effective tool for removal of heat from very small electronic devices. In this study various literature related to CLPHP are studied and various parameters that effect the performance of CLPHP. It was found from literature that length of pipe, Number of turns, cooling fluid effect the performance of pipe.

Authors and Affiliations

Keywords

Related Articles

SOCIAL SUPPORT AND JOB SATISFACTION AMONG THE SCHOOL TEACHERS IN TIRUCHIRAPPALLI EDUCATIONAL REVENUE DISTRICT, TAMIL NADU, INDIA

Teachers’ role in society in general and in education has been changing with time but the importance of this position is same. The teacher is the pre-requisite of the success of educational programmes. The main quality o...

CONCEPTUAL STUDY OF ROLE OF AYURVEDA IN PREVENTION OF LIFESTYLE DISEASES

Ayurveda is the science of life, guiding in maintaining health and curing of diseases by balancing doshas-dhatus-malas and jatharagni. Ahara, nidra and brahmacharya form the pillars of health as per Ayurveda. Lifestyle d...

IMPACT OF ICT IN DISTANCE EDUCATION AND TEACHER PERCEPTION TOWARDS KNOWLEDGE OF ICT TOOLS

The Information and Communication Technology (ICT) can be one of the important tools while teaching at under graduate and post graduate level. It is being popular at education sector because of their different modes of o...

A COMPARATIVE STUDY OF GIRL’S PHYSICAL SCIENCE PERFORMANCE BETWEEN CO-EDUCATIONAL AND SINGLE SEX SCHOOLS IN SWAZILAND

The major objective of the study was to compare the performance of girls studying physical science in single sex schools and those in co-educational schools. Three research questions were raised and one hypothesis formul...

A STUDY ON EMPLOYER BRANDING WITH SPECIAL REFERENCE TO HIROTEC INDIA PRIVATE LIMITED

Employer branding is the most recent and current trend in every organization today. Due to lack of employer branding organizations are facing lots of problems in retaining talented workforce especially in industries. The...

Download PDF file
  • EP ID EP210773
  • DOI 10.5281/zenodo.59257
  • Views 86
  • Downloads 0

How To Cite

(2016). A REVIEW OF EXPERIMENTAL STUDY AND CFD BASED SIMULATION OF CLOSED LOOP PULSATING HEAT PIPE. International journal of research -GRANTHAALAYAH, 4(7), 265-270. https://europub.co.uk/articles/-A-210773