A REVIEW OF LITERATURE ON THERMAL DESIGN OF FORCED DRAFT COUNTER TO CROSS FLOW AIR COOLED HEAT EXCHANGER

Abstract

Heat exchangers are equipment that transfers heat from one medium to another. An air cooled heat exchanger, or ACHE, is simply a pressure vessel which cools a circulating fluid within finned tubes by forcing ambient air over the exterior of the tubes. In cross flow exchangers, the hot and cold fluids move perpendicular to each other. Some actual heat exchangers are a mixture of cross flow and counter flow (Known as Counter to Cross Flow Heat Exchangers) due to design features. The proper design, operation and maintenance of heat exchangers will make the process energy efficient and minimize energy losses. Heat exchanger performance can deteriorate with time, off design operations and other interferences such as fouling, scaling etc. It is necessary to assess periodically the heat exchanger performance in order to maintain them at a high efficiency level. This section comprises certain proven techniques of monitoring the performance of heat exchangers, coolers and condensers from observed operating data of the equipment.

Authors and Affiliations

Parag Mishra

Keywords

Related Articles

 Designing Mobility using Distance Routing Effect Algorithm

 An ad-hoc network signifies a solution designed for a specific problem or task and it is an independent network that provides usually temporary peer-to-peer connectivity without relying on a complete network infr...

 A CLASSIFICATION OF ALMOST LORENTZIAN SASAKIAN MANIFOLD

 In 2011, R. Nivas and A. Bajpai [6] studied on generalized Lorentzian Para-Sasakian manifolds. Hayden [2] introduced the idea of metric connection with torsion tensor in a Riemannian manifold. In 1970, K.Yano [7]s...

 Automated LPG Billing and Security System Using Wireless Sensor Networks

 Wireless Sensor Networks are networks consisting of sensors as their main components. Sensors are arranged and connected with each other dynamically. We are implementing a system which can remotely monitor and co...

 Simple and Cost Effective Environment Monitoring System

 Monitoring Environmental factors such as temperature measurement, light intensity, relative humidity and air composition are not only important for industrial purposes but also a cause of growing concern in our da...

Effect of Aquo-Glycolic Media of Anodic Oxides on Zr

The surface of zircaloy-4 anodized at a constant current density of 4mA.cm ethylene glycol at a potential 0–187V, was characterized by means of surface science technique AFM with micro and nanostructures. It was found...

Download PDF file
  • EP ID EP154106
  • DOI 10.5281/zenodo.50408
  • Views 39
  • Downloads 0

How To Cite

Parag Mishra (30). A REVIEW OF LITERATURE ON THERMAL DESIGN OF FORCED DRAFT COUNTER TO CROSS FLOW AIR COOLED HEAT EXCHANGER. International Journal of Engineering Sciences & Research Technology, 5(4), 777-785. https://europub.co.uk/articles/-A-154106