A Simple Method for Removal of the Distal Segment of a Broken Femoral Intramedullary Nail: A Case Report
Journal Title: Malaysian Orthopaedic Journal - Year 2012, Vol 6, Issue 2
Abstract
We report a method for removing the distal segment of a broken locked intramedullary nail secondary to nonunion of the femur following radiotherapy for fibromatosis. A Kirschner wire with one tip fashioned into a hook was used to remove the distal segment without opening with the nonunion site. Details of the procedure are described.
Authors and Affiliations
KL Pan, Reuben PR
Use of Titanium Elastic Nails in the Adult Diaphyseal Humerus Fractures
Introduction: Humerus shaft fractures in adults can be managed conservatively with functional braces or operatively with plate osteosynthesis or with intramedullary nailing. Conventionally humerus intramedullary nailing...
Brodie’s Abscess of Posterior Ilium with Gluteal Syndrome, an Unusual Cause of Paediatric Low Back Pain: A Case Report
Brodie’s abscess is a variety of subacute osteomyelitis with a long duration of presentation and intermittent pain. It usually involves the metaphyseal region of long bones of the lower limbs. Brodie’s abscess of pelvic...
Metastatic Adenocarcinoma to the Wrist Presenting as Carpal Tunnel Syndrome: A Report of an Unusual Cause
Secondary metastases to the hand are rare, accounting for 0.1% of all metastases, and commonly involve bones 1,2. Soft tissue involvement is extremely unusual although it is significantly more common in carcinoma than sa...
A Rare Incidence of Breakage of tip of Micropituitary Forceps during Percutaneous Discectomy - How to Remove it: A Case Report
Breakage of the tip of the micropituitary forceps during spine surgery is a rare occurrence. Retrieval of the broken tip could be a challenge in minimally invasive surgeries due to limitation of access and retrieval inst...
Safety Issues and Neurological Improvement following C1-C2 Fusion using C1 Lateral Mass and C2 Pedicle Screw in Atlantoaxial Instability
The evolution of instrumentation methods for C1-C2 fusion from the use of posterior wiring methods to transarticular screws and C1 lateral mass with C2 pedicle screw construct have improved fusion rates to almost 100%. H...