A Simple Procedure for Preconcentration of Trace Amounts of Co (II), Cu (II) and Ni (II) Using A New Chelating Resin

Journal Title: Saudi Journal of Engineering and Technology - Year 2018, Vol 3, Issue 5

Abstract

Abstract: A new method for preconcentration of ultratrace amounts of Co (II), Ni(II) and Cu(II) ions in various matrices has been proposed. The method is based on the adsorption and chelation of the metal ions on Amberlite XAD-4 resin modified with Quinol via azotisation prior to their determination by standard spectrophotometric method. The effect of pH, type, concentration and volume of eluent, sample volume,flow rates of sample and elution solutions, and interfering ions have been investigated. The optimum pH for retention of the metal ion were10.0, 7.0 and 7.0 respectively. Eluent for quantitative elution was 5 ml of 2 mol l−1 HCl. The optimum sample and eluent flow rates were found to be 2.5 ml min−1. The sorption capacity of the resin was found to be 0.60, 0.45 and 0.52mmolg-1 for Co (II), Ni (II) and Cu (II) respectively. The preconcentration factor of the method was 250 for all the metals. The detection limit values were in the range of 3.0- 5.0 µgl-1. The accuracy of the method was confirmed by analyzing standard synthetic mixtures and standard addition methods. This procedure was applied to the determination of Cobalt, Nickel and Copper from various water samples and SRM’s. Keywords:Amberlite XAD-4, Functionalization, Quinol, Preconcentration, Trace metal.

Authors and Affiliations

Syed Kashif Ali

Keywords

Related Articles

Efficiency of Cyperusesculentus as a biofilter in treatment of domestic waste water

Abstract: This study presents treatment of domestic wastewater collected from the Harmony Lodge IfiteAwka, Anambra state using laboratory scale constructed wetland vegetated with Cyperusesculentus(tiger nut)plant as bio...

Modeling and Simulation Issues On Standalone Two Axis Sun Tracker

Abstract: This paper proposes a new model for design of standalone two axis sun-tracker (SATAST) and some considerations regarding design, modeling and control solutions. Proposed overall system model and sub-models are...

Ontology Based Automatic Text Mining Using TF and IDF Algorithms for Summarization of Multiple Files

Abstract: In the present world, due to tremendous development in technology, a huge amount of information is available everywhere. Therefore, it is difficult for the users to understand the main content of the entire doc...

The Effects of Transesterification and Blending on the Fatty Acid Profiles of Vegetable Oils

Abstract: Vegetable oils are basically of fatty acids and the amount present can affect the properties of the resulting biodiesel. The aim of this study is to investigate how the transesterification affects the fatty aci...

Modeling and Simulation of Lac Operon Regulation of E. coli bacterium Using Intelligent Fuzzy System

Abstract: Current methodologies in displaying dynamic organic frameworks regularly need fathomability, particularly for users without scientific foundation. In this paper propose another way to deal with defeat such conf...

Download PDF file
  • EP ID EP402274
  • DOI -
  • Views 162
  • Downloads 0

How To Cite

Syed Kashif Ali (2018). A Simple Procedure for Preconcentration of Trace Amounts of Co (II), Cu (II) and Ni (II) Using A New Chelating Resin. Saudi Journal of Engineering and Technology, 3(5), 286-292. https://europub.co.uk/articles/-A-402274