A Simple Procedure for Preconcentration of Trace Amounts of Co (II), Cu (II) and Ni (II) Using A New Chelating Resin

Journal Title: Saudi Journal of Engineering and Technology - Year 2018, Vol 3, Issue 5

Abstract

Abstract: A new method for preconcentration of ultratrace amounts of Co (II), Ni(II) and Cu(II) ions in various matrices has been proposed. The method is based on the adsorption and chelation of the metal ions on Amberlite XAD-4 resin modified with Quinol via azotisation prior to their determination by standard spectrophotometric method. The effect of pH, type, concentration and volume of eluent, sample volume,flow rates of sample and elution solutions, and interfering ions have been investigated. The optimum pH for retention of the metal ion were10.0, 7.0 and 7.0 respectively. Eluent for quantitative elution was 5 ml of 2 mol l−1 HCl. The optimum sample and eluent flow rates were found to be 2.5 ml min−1. The sorption capacity of the resin was found to be 0.60, 0.45 and 0.52mmolg-1 for Co (II), Ni (II) and Cu (II) respectively. The preconcentration factor of the method was 250 for all the metals. The detection limit values were in the range of 3.0- 5.0 µgl-1. The accuracy of the method was confirmed by analyzing standard synthetic mixtures and standard addition methods. This procedure was applied to the determination of Cobalt, Nickel and Copper from various water samples and SRM’s. Keywords:Amberlite XAD-4, Functionalization, Quinol, Preconcentration, Trace metal.

Authors and Affiliations

Syed Kashif Ali

Keywords

Related Articles

Roughness Prediction Modelling for Flexible Pavement in Low Volume Roads in State of Tamil Nadu in India

Abstract: In this research paper, prediction model is developed for the progression of roughness, which is the most important performance indicator of flexible pavements. Since many stretches of flexible pavements in vil...

Experimental Investigation of Flow Characteristics over Crump Weir with Different Conditions

Abstract:Weirs are the most extensively used hydraulic structures in the different fields of hydraulics, environmental, irrigation, and chemical engineering, as flow measuring and flow control devices in open Channels. T...

Empirical Analysis of ICT Constraints Affect the Performance of Small & Medium Enterprises in Pakistan

Abstract:The purpose of this paper is to examine the Information and communication technology (ICT) challenges are being faced by the small and medium enterprises (SMEs) in the service sector of Pakistan. Quantitative re...

Evaluation of the Reliability, Resilience and Vulnerability of Jebba Hydropower Reservoir Operation, Nigeria

Abstract:The operational status of a hydropower dam is described as either satisfactory or unsatisfactory. The ability of existing and proposed hydropower dams to operate satisfactorily under wide range of possible futur...

First geometric-Arithmetic Index,k_r-gluing graph, complete graph, Web graph, wheel graph, k-bridge graph.

Abstract: In order to meet with the requirement of the campus shopping, we put forward the design of campus logistics service platform to serve students’ shopping. In the platform the campus service provider put their sa...

Download PDF file
  • EP ID EP402274
  • DOI -
  • Views 148
  • Downloads 0

How To Cite

Syed Kashif Ali (2018). A Simple Procedure for Preconcentration of Trace Amounts of Co (II), Cu (II) and Ni (II) Using A New Chelating Resin. Saudi Journal of Engineering and Technology, 3(5), 286-292. https://europub.co.uk/articles/-A-402274