A study of the advantages of the new device for percutaneous entry point in greater trochanter for any intra medullary fixation of the femur compared to the conventional methods

Journal Title: Medpulse International Journal of Orthopedics - Year 2019, Vol 10, Issue 2

Abstract

Background:In the past the most common surgery around the hip was DHS and Barrel plate for any trochanteric fractures. Of late the commonest surgeries done on the Femur are Proximal Femoral Nail (PFN) or the Interlocking Nailing for the fractures of the Femur or supracondylar nailing of the Femur. Aim:To study the advantages of the new device for percutaneous entry point in Greater Trochanter for any intra medullary fixation of the Femur compared to the conventional methods.Objectives: To access advantages of this new device over the conventional device used for the intramedullary femur entry point. The following intraoperative characteristics were compared by usage of new device and conventional device.1)C-Arm exposure time, 2)Technical difficulties during surgery along with complications, 3)Duration of surgery, 4)Blood loss, Materials and Methods:A total of sixty four cases are being treated from November 2017 to October 2018 at Bhaskar Medical College and Bhaskar General Hospital Yenkapally,thirty two cases each by this method of percutaneous entry point in the Trochanter using this new device and conventional device respectively for the Trochanteric fractures and for the fractures of shaft of the Femur.The device is designed by the author and his team indigenously in the work shop of the Mechanical engineering of Joginpally Institute of Engineering and Technology.All the patients gave the informed consent for inclusion into study and the study was authorized by the local ethical committee.Results:We have done this study in 64 patients, 32 patients each by new device and conventional device respectively. With the use of new device, there was ease getting into the exact point of entry in the Trochanter, the comfort of getting both AP and Lateral views of the C- arm pictures with avoidances of unnecessary exposure to radiation and minimal blood loss compared to the use of conventional device.Conclusion:The study has found that the new device is very effective and advantageous compared to the conventional device for percutaneous entry point in Greater Trochanter for any intra medullary fixation of the Femur

Authors and Affiliations

VS Ravindranath, BSreekanth Rao

Keywords

Related Articles

The operative treatment of displaced middle one third clavicle shaft fracture: Experience of 30 cases

Background: Clavicle fracture is a common traumatic injury around shoulder girdle due to its subcutaneous position. Open reduction and internal fixation can be achieved with intramedullary devices or plate fixation. Aim:...

A study of the advantages of the new device for percutaneous entry point in greater trochanter for any intra medullary fixation of the femur compared to the conventional methods

Background:In the past the most common surgery around the hip was DHS and Barrel plate for any trochanteric fractures. Of late the commonest surgeries done on the Femur are Proximal Femoral Nail (PFN) or the Interlocking...

A study of clinical profile of patients with fracture of distal end radius at tertiary health care centre

Background: Sir Abraham Colles, an Ireland surgeon, classically described the fracture in the Edinburgh Medical Surgical journal in 1814. Aims and Objectives: To study clinical profile of Patients with Fracture of distal...

The analysis of factors causing functional disabilities in osteoarthritis of the knee: A prospective study

Osteoarthritis(OA) of the knee is one of the most common diagnoses made in the Orthopaedic out patient department and is also the most common type of arthritis in India. The prevalence of OA is high in the elderly, espec...

Role of intravenous zoledronic acid in treatment of osteoporosis

Background: Zoledronic acid is used this to prevent or treat osteoporosis in men and post-menopausal women and patients on glucocorticoids. However, the clinical evidence in the effect of Zoledronic acid on osteoporosis...

Download PDF file
  • EP ID EP617241
  • DOI 10.26611/10201028
  • Views 43
  • Downloads 0

How To Cite

VS Ravindranath, BSreekanth Rao (2019). A study of the advantages of the new device for percutaneous entry point in greater trochanter for any intra medullary fixation of the femur compared to the conventional methods. Medpulse International Journal of Orthopedics, 10(2), 40-44. https://europub.co.uk/articles/-A-617241