A Study on Effect of Geometric Patterns and Material on Stress Distribution in Dental Implant System: A 3-Dimensional Finite Element Analysis

Abstract

This study investigate the modified implant body design by varying thread pitch, helix angle to study the influence of the parameters on stability and stress distribution at the implant/bone interface, and also identify the optimum implant structure, suitable for reliable rehabilitation and quicker osseointegration under biomechanical loading conditions. The study was classified into three groups: Group 1 (standard pitch), Group 2 (helix angle) and Group 3 (biocompatible material: titanium). A three dimensional finite element model of three variants were designed with the standard pitch group 2.2 mm and single thread, double thread and triple thread, respectively. The results obtained under normal load applied for titanium showed maximum Von Mises stresses at interface of dental implant structure and cortical bone. The results show that the thread pitch and helix angle plays a substantial role in enhancing the implant stability and reducing the bone stress. Moreover, from the biomechanical analysis for the screwed implant structure with thread pitch of 2.2 mm with double thread, proves to be optimal.

Authors and Affiliations

Nayana Prabhu, Nithesh Naik, Vathsala Patil, Udit Rathee, Amina Barkallah

Keywords

Related Articles

On the Thermoplasticity Constitutive Relations for Isoptopic and Transversely Isotropic Materials

The widely used engineering construction materials such as fiber and laminated composite materials are usually under the thermomechanical forces and undergoes thermoplastic deformations. These composites may be considere...

Stress Analysis of High Speed Four Bar Mechanism

The multi-body four bar mechanical system is an rigid links assemblage of assumed revolute joints and crank rotating motion for complete cycle, the links which produce relative motion. In higher speed mechanisms the assu...

Effective Time Domain Features for Identification of Bearing Fault using LDA and NB Classifiers

Recently, the mechanical fault detection of an induction motor (IM) from vibration signals using pattern recognition has proven to be an effective method. This paper has studied for the first time statistical time domain...

Generating Disassembly Sequences of Mechanical Assembly from Step-Cad Model

Lot of research works have been made on identifying feasible disassembly sequences for an assembly. However, those research works were concentrated on an assembly in which the parts must have single step to disassemble....

Review: Effects of Inlet Conditions on Diffuser Performance

This paper presents the effects of various geometrical as well as fluid dynamics governing parameters on diffusers performance with significance on the inlet conditions for different area ratio in diffusers. The effects...

Download PDF file
  • EP ID EP672251
  • DOI 10.24247/ijmperdoct201966
  • Views 75
  • Downloads 0

How To Cite

Nayana Prabhu, Nithesh Naik, Vathsala Patil, Udit Rathee, Amina Barkallah (2019). A Study on Effect of Geometric Patterns and Material on Stress Distribution in Dental Implant System: A 3-Dimensional Finite Element Analysis. International Journal of Mechanical and Production Engineering Research and Development (IJMPERD ), 9(5), 743-752. https://europub.co.uk/articles/-A-672251