A STUDY ON INFLUENCE OF MASONRY INFILLS AND SHEAR WALL ON THE SEISMIC PERFORMANCE OF R.C FRAMED BUILDING

Abstract

The study offerings the practice for seismic performance estimation of asymmetric reinforced concrete frame buildings through ground soft storey built on a perception of the capacity spectrum method. Previous recent seismic tremors in many parts of India and globe have discovered the issue concerning the weakness of present structures. The present structures, which were designed and constructed based on earlier code requirements, do not content requirement of current seismic code and design practice. “ETABS” is used as a structural analysis tool for analyzing building models . Mainly which effect the mass, strength, stiffness and deformability of the structure & other important components which influence the above properties of the structures includes in analytical model of the building. To study the effect of infill and concrete core wall & shear wall at different positions during earthquake, seismic analysis using both linear static, linear dynamic (response spectrum method) as well as non-linear static procedure (pushover) has been performed. It is an attempt to study the performance of multistoried reinforced concrete building frame due to influence/provision of masonry infill’s and shear wall, five (5) building models (11 storey each) with identical building plan and asymmetry in elevation were study and analyzed. By performing Equivalent static, response spectrum method the deflections at each storey level has been compared as well as to determine capacity, demand and performance level of the considered building models the pushover method is adopted.

Authors and Affiliations

Md Ibrahim Khaleel

Keywords

Related Articles

ABSTRACT BASED CRYPTOGRAPHY

The issues of confidentiality, authenticity and anonymity have been known from long time in Security i.e. Cryptography , and the idea of provable security is the basic foundation for most, if not all, latest cryptograph...

 EXHAUST EMISSION CONTROL BY USING COPPLER PLATE AND AMMONIA SOLUTION

 As we all know the numbers of vehicles are increasing at a very fast rate therefore causing great increase in environmental pollution which needs to be controlled. For reducing this pollution government has given...

 Simulating Model of UWB System for SUI Channel

 This paper is concerned about the performance of UWB system in the multiuser environment. The existence of several multiuser access can cause a significant performance degradation and hence the transmission rate....

Power Quality Improvement in PMBLDCM Drive using PFC SEPIC Converter for Air Conditioner

In this paper, an improved power quality converter employing Single Ended Primary Inductor (SEPIC) converter topology is used to feed a permanent magnet brushless DC motor (PMBLDCM) drive. Normally, the PMBLDCM drive h...

 Peristaltic Transport of a Herschel-Bulkley Fluid in Contact With a Newtonian Fluid in a Circular Tube

 Peristaltic flow of a Herschel-Bulkley fluid in contact with a Newtonian fluid in a circular tube is studied. The interface which is a stream line is determined by solving a non-linear equation. The expressions fo...

Download PDF file
  • EP ID EP159124
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

Md Ibrahim Khaleel (2015). A STUDY ON INFLUENCE OF MASONRY INFILLS AND SHEAR WALL ON THE SEISMIC PERFORMANCE OF R.C FRAMED BUILDING. International Journal of Engineering Sciences & Research Technology, 4(12), 744-756. https://europub.co.uk/articles/-A-159124