A Survey of the quantity and type of biological aerosols in selected wards of a teaching hospital in Ghazvin

Journal Title: Electronic Physician - Year 2016, Vol 8, Issue 4

Abstract

INTRODUCTION: Bioaerosols are agents that can cause infection, allergy or induce other toxic effects in the human body. If the person exposed to such particles is not capable of their destruction or elimination from the body, the established chemical and physiological disorders can result in disease or death. The aim of this study was to assess the concentrations of bioaerosols in several wards of a teaching hospital. METHODS: Given that gas air-conditioners (split and window types) were used for ventilation in the eye operating room, internal intensive care unit, and the respiratory isolation room, these wards were selected for passive sampling. Sterile plates containing culture medium were exposed for two hours to the wards' indoor ambient air. After this time, they were transferred to a lab to undergo incubation, colony count, and identification of the microorganisms. The data were analyzed using SPSS software, version 18, and the significance level of less than 0.05 was used. RESULTS: Based on our findings, the highest colony-forming bacterial unit was observed 22 cfu/plate/h in the eye operating room and, the highest colony-forming fungal unit was observed 4 cfu/plate/h in the internal intensive care unit. Based on the results of the differential tests, the most prevalent bacteria identified were Staphylococcus epidermidis (75%) in the air of eye operating room and Staphylococcus saprophyticus (52%) in the internal intensive care unit and isolation room. The most prevalent identified fungi in the air of selected wards were related to Alternaria alternata (43%), Aspergillus flavus (24%), Penicillium (36%) and Curvularia (21%) types. Based on Spearman's correlation test, no significant relationship was observed between the factor of temperature and the number of fungal and bacterial colonies (r = 0.201, p = 0.42; r = -0.197, p = 0.41). Moreover, a meaningful relationship was observed only between the number of individuals and the bacterial colonies present in the air (r = 0.749, p = 0.0001). CONCLUSION: Comparing the number of diagnosed colonies by 25 cfu/plate/h value showed that the numbers of colonies in all samples were lower than the mentioned values. So, the air-conditioning systems' performance in reducing the number of bioaerosols in the studied wards was satisfactory. However, since the remaining bacterial and fungal contamination can cause serious infections in patients, it is highly necessary that the cleaning intervals and replacement time points of such filters be programmed based on the number of individuals present in the wards and their active surgical hours

Authors and Affiliations

Eslami A, Karimi F, Rajabi Z

Keywords

Related Articles

A systematic review of the relationship between dystemprament (sue Mizaj) and treatments and management of diseases (Ilaj and Eslah-e-Mizaj)

BACKGROUND: Temperament refers to four different humors differentiating in individuals and, as a result, proposes specific therapy for diseases as well as special types of management (avoidance). OBJECTIVE: The aim of t...

Association between Organizational Commitment and Personality Traits of Faculty Members of Ahvaz Jundishapur University of Medical Sciences.

Individual characteristics are important factors influencing organizational commitment. Also, committed human resources can lead organizations to performance improvement as well as personal and organizational achievement...

Analytical investigation of magnetic field effects on Proton lateral deflection and penetrating depth in the water phantom: A relativistic approach

BACKGROUND: Integrated proton therapy - MRI systems are capable of delivering high doses to the target tissues near sensitive organs and achieve better therapeutic results; however, the applied magnetic field for imaging...

Profile of peptic ulcer disease and its risk factors in Arar, Northern Saudi Arabia

BACKGROUND: Peptic ulcer disease is a multifactorial health problem, and its prevalence and risk factors have changed considerably within the past century. OBJECTIVE: To determine the prevalence of peptic ulcer among th...

 Comparative study of lipid profile in non-smokers, chronic smokers, and chronic smokers with acute myocardial infarction in men

 Introduction: Smoking is a major risk factor in the genesis of coronary atherosclerosis and development of coronary heart disease. Smoking may alter normal plasma lipoprotein levels. The present study was undertake...

Download PDF file
  • EP ID EP324185
  • DOI 10.19082/2281
  • Views 64
  • Downloads 0

How To Cite

Eslami A, Karimi F, Rajabi Z (2016). A Survey of the quantity and type of biological aerosols in selected wards of a teaching hospital in Ghazvin. Electronic Physician, 8(4), 2281-2285. https://europub.co.uk/articles/-A-324185