A Survey of the quantity and type of biological aerosols in selected wards of a teaching hospital in Ghazvin

Journal Title: Electronic Physician - Year 2016, Vol 8, Issue 4

Abstract

INTRODUCTION: Bioaerosols are agents that can cause infection, allergy or induce other toxic effects in the human body. If the person exposed to such particles is not capable of their destruction or elimination from the body, the established chemical and physiological disorders can result in disease or death. The aim of this study was to assess the concentrations of bioaerosols in several wards of a teaching hospital. METHODS: Given that gas air-conditioners (split and window types) were used for ventilation in the eye operating room, internal intensive care unit, and the respiratory isolation room, these wards were selected for passive sampling. Sterile plates containing culture medium were exposed for two hours to the wards' indoor ambient air. After this time, they were transferred to a lab to undergo incubation, colony count, and identification of the microorganisms. The data were analyzed using SPSS software, version 18, and the significance level of less than 0.05 was used. RESULTS: Based on our findings, the highest colony-forming bacterial unit was observed 22 cfu/plate/h in the eye operating room and, the highest colony-forming fungal unit was observed 4 cfu/plate/h in the internal intensive care unit. Based on the results of the differential tests, the most prevalent bacteria identified were Staphylococcus epidermidis (75%) in the air of eye operating room and Staphylococcus saprophyticus (52%) in the internal intensive care unit and isolation room. The most prevalent identified fungi in the air of selected wards were related to Alternaria alternata (43%), Aspergillus flavus (24%), Penicillium (36%) and Curvularia (21%) types. Based on Spearman's correlation test, no significant relationship was observed between the factor of temperature and the number of fungal and bacterial colonies (r = 0.201, p = 0.42; r = -0.197, p = 0.41). Moreover, a meaningful relationship was observed only between the number of individuals and the bacterial colonies present in the air (r = 0.749, p = 0.0001). CONCLUSION: Comparing the number of diagnosed colonies by 25 cfu/plate/h value showed that the numbers of colonies in all samples were lower than the mentioned values. So, the air-conditioning systems' performance in reducing the number of bioaerosols in the studied wards was satisfactory. However, since the remaining bacterial and fungal contamination can cause serious infections in patients, it is highly necessary that the cleaning intervals and replacement time points of such filters be programmed based on the number of individuals present in the wards and their active surgical hours

Authors and Affiliations

Eslami A, Karimi F, Rajabi Z

Keywords

Related Articles

Safe use of capecitabine-cisplatin in metastatic gastric carcinoma with severe liver dysfunction: a case report from Algeria

Due to its high incidence and poor prognosis, gastric cancer is an important health problem worldwide. The liver is the most frequent site of metastases. Advanced cancer in the setting of liver dysfunction poses a dilemm...

The effect of intervention using the PRECEDE-PROCEED model based on quality of life in diabetic patients

BACKGROUND: Poor quality of life is common among diabetic patients, and educational intervention is one of the most effective strategies to improve the quality of life for chronic patients. OBJECTIVES: To determine the...

Desmopressin versus Oxybutynin for Nocturnal Enuresis in Children in Bandar Abbas: A Randomized Clinical Trial.

Nocturnal enuresis is among the most common disorders in children. Several pharmacological and non-pharmacological treatments are available for nocturnal enuresis. Studies for reaching the best pharmacological treatment...

Association of hematological indices with prediabetes: A cross-sectional study

BACKGROUND: Prediabetes is a condition that occurs when blood glucose levels are higher than normal, but not high enough to be classified as diabetes. Prediabetic people have an increased risk of developing type 2 diabet...

A systematic review study of therapeutic effects of Matricaria recuitta chamomile (chamomile)

INTRODUCTION: Matricaria recuitta chamomilla is a plant that grows and is cultivated in some parts of Iran. The aim of this study was to overview the therapeutic effects of this valuable plant. This systematic review was...

Download PDF file
  • EP ID EP324185
  • DOI 10.19082/2281
  • Views 86
  • Downloads 0

How To Cite

Eslami A, Karimi F, Rajabi Z (2016). A Survey of the quantity and type of biological aerosols in selected wards of a teaching hospital in Ghazvin. Electronic Physician, 8(4), 2281-2285. https://europub.co.uk/articles/-A-324185