Accuracy and Precision of Measured Blood Sugar Values by Three Glucometers Compared to the Standard Technique

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 4

Abstract

Introduction: The prevalence of diabetes mellitus has magnified, globally. Being cost effective and user friendly, using the glucometer systems has become more widespread. However, despite their advantages, there are controversies regarding their accuracy and precision. Aim: To determine the accuracy and precision of the common glucometers of Bionime, Accu-check, and Beurer compared with the laboratory technique. Materials and Methods: In a cross-sectional study, 257 patients of a general internal unit of Imam Reza hospital of Kermanshah were recruited. The blood sample of the subjects was transferred to the laboratory, then, two samples of capillary blood were tested by the three glucometers. The data was entered into a checklist, then entered to SPSS-16.0 software, and analyzed by descriptive and inferential statistics. Results: In this study, there was a positive correlation between the three blood glucose measurement methods with the standard approach, significantly, which indicates acceptable accuracy. However, this correlation was higher in the Beurer Glucometer (r=0.976, p<0.001). There were no significant differences in repeated measurements of blood glucose in the glucometers of Beurer (t=0.96, p=0.92), and Bionime (t=0.50, p=0.61) by paired t-test, but this test was significant for Accu-chek system (t=2.7, p=0.006). Conclusion: With respect to the acceptable accuracy and precision of Beurer and Bionime glucometers, it is suggested to use these methods for diabetic patients at homes as well as in the hospital units.

Authors and Affiliations

Shadi Khakpour Kermani, Alireza Khatony, Rostam Jalali, Mansur Rezaei

Keywords

Related Articles

Histogram Based Synovitis Scoring System Using Ultrasound Images of Rheumatoid Arthritis

ABSTRACT Introduction: The gray scale Ultrasound (US) imaging aids in assessing activity of Rheumatoid arthritis condition through classification of synovitis and is able to estimate the disease progression. The gray sha...

Psychometric Utility in Determining Dental Organizational Attribute: A Cross Sectional Study in Ghaziabad, India

Introduction: Psychometrics is the field of research involved with the objective measurement of finesse and intelligence, skills, temperament, personality traits, and educational success and technique of psychological me...

Knowledge, Attitude and Practice of Smoking among Pharmacy Students: Findings from a Public University

ABSTRACT Introduction: Smoking causes substantial preventable morbidity, mortality and financial burdens. It is the main risk factor for many diseases and a significant cause of death. Smoking prevalence is high internat...

Neurological Manifestations in Systemic Lupus Erythematosus: A Single Centre Study from North East India

Introduction: Neurological manifestations although common in Systemic Lupus Erythematosus (SLE), are often not recognized due to their diversed and varied presentation. Therefore, the study was planned to highlight the p...

Nature of Hard Tissues in Oral Pathological Lesions –Using Modified Gallego’s Stain

Introduction: Histological stains are dyes that bind to various tissues. Special stains form an integral part of routine histopathology as an adjunct to Haematoxylin and Eosin (H&E), and give meaningful diagnostic inform...

Download PDF file
  • EP ID EP337880
  • DOI 10.7860/JCDR/2017/23926.9613
  • Views 113
  • Downloads 0

How To Cite

Shadi Khakpour Kermani, Alireza Khatony, Rostam Jalali, Mansur Rezaei (2017). Accuracy and Precision of Measured Blood Sugar Values by Three Glucometers Compared to the Standard Technique. Journal of Clinical and Diagnostic Research, 11(4), 5-8. https://europub.co.uk/articles/-A-337880