Accuracy of free hand technique of transpedicular screw fixation in correction of spinal deformities

Journal Title: International Journal of Orthopaedics Sciences - Year 2017, Vol 3, Issue 3

Abstract

Introduction: Pedicular screw fixation is now the novel technique to correct spinal deformities. Navigation or CT guided systems are not easily available in Indian scenario. Free hand technique of pedicle screw insertion is commonly practiced for degenerative spine and traumatic spine with fluoroscopic guidance, but for deformed spine fluoroscopy may not be always helpful. AIM: we intend to evaluate accuracy and safety free hand technique in kyphoscoliotic spine. Material and Methods: Twenty consecutive patients suffering from kyphoscoliosis underwent posterior stabilization using a total of 260 titanium/stainless steel transpedicular screws. The position of the screws inserted into the deformed spine was evaluated by postoperative computed axial tomography (CAT) scans. All patients underwent 3-mm thin-section postoperative CT. Pedicle perforations were classified as either medial or lateral breech and distance was measured of breach. Results: Of the 260 screws inserted into the deformed scoliotic spine 27 screws showed moderate lateral cortical perforation whereas 11 screws showed moderate medial cortical breech. These screws showed cortical perforation in the range of 2.1-4.0mm.One screw each showed cortical breech in the range of 4.1-6.0mm on medial and lateral side. Conclusion: This study concludes that with good knowledge of anatomy of spine, free hand thoracic pedicle screw insertion technique for the surgical treatment of normal and deformed thoracic spines without any radiographic guidance and/or intraoperative tracking devices appears to be a safe, and reliable procedure.

Authors and Affiliations

Dr. Kunal Dhurve, Dr. Vishal Patil

Keywords

Related Articles

Comparative analysis of the functional outcome of arthroscopic anterior cruciate ligament reconstruction using quadrupled hamstring graft fixed with bio absorbable interference screw against titanium interference screw

Anterior cruciate ligament injury is one of the most common injuries around knee and poses quiet a lot management controversies. Anterior cruciate ligament has a pivot role in function and stability of the knee joint alo...

Operative results of proximal femoral nailing in subtrochanteric fracture femur using pyriformis fossa entry

Introduction: Subtrochanteric fracture of the femur is a variant of the peritrochanteric fracture of the femur. It extends upto 5 cm below the lesser trochanter. The incidence is relatively much lower (3.9% of all the pr...

Radiological assessment of closure time of around elbow secondary ossification centers, in Khartoum hospital, Khartoum north hospital, Omdurman hospital, police hospital, and Umbadda hospital, in Khartoum, Sudan (December 2009-2010)

Background: Elbow joint is characterized by 6 secondary ossification centers; in the capitulum, trochlea, lateral and medial epichondyles, olecranon and head of the radius. They are present on plane elbow radiograph at d...

Effectiveness of vacuum assisted negative pressure wound therapy in grossly contaminated wounds

Management of open highly contaminated wound due to high velocity trauma (road traffic accidents) is always a challenging problem for surgeon for primary definite management of fracture. For such grossly contaminated wou...

Supracutaneous plate: A comparable alternative to external fixator in the treatment of open fracture

Open fracture is one of the common health care problems in clinical orthopedic practice. Incidence of open fracture rate is increasing, especially in working age groups in industrialized society. Treatment of open fractu...

Download PDF file
  • EP ID EP500018
  • DOI 10.22271/ortho.2017.v3.i3j.108
  • Views 132
  • Downloads 0

How To Cite

Dr. Kunal Dhurve, Dr. Vishal Patil (2017). Accuracy of free hand technique of transpedicular screw fixation in correction of spinal deformities. International Journal of Orthopaedics Sciences, 3(3), 701-706. https://europub.co.uk/articles/-A-500018