Abstract

Employment of photovoltaic (PV) distributed Generation in the distribution system, leads to improvement of network voltage profile and power quality. On the other hand, it cause miscoordination between fuses and recloser. In this paper an adaptive method is presented to maintain coordination between fuse and recloser. This method is based on a modification of fast operation curve of recloser, proportional to the lateral fuse maximum fault current to recloser current which is located at the beginning of the feeder. Simulation results show the performance of the proposed methods for different fault scenarios, variation of PV penetration and different fault resistance. Based on the presented method, proportional to PVs penetration the protection coordination index (PCI) determined in fault period. Then, according to this index, time dial setting (TDS) of recloser fast operation modified adaptively. Finally, new recloser trip time calculated in this conditions for fuse saving. Simulation results show the performance of the proposed methods for different fault scenarios, variation of PV penetration and different fault resistance.

Authors and Affiliations

Farzad Hajimohammadi, Bahador Fani

Keywords

Related Articles

Novel Fuzzy-IWO Method for Reconfiguration Simultaneous Optimal DG Units Allocation

This paper presents a new hybrid method for optimal multi-objective reconfiguration simultaneous determining the optimal size and location of Distributed Generation (DG) in a distribution feeder. The purposes of this res...

A New Control System for a Dual Stator-Winding Cage Rotor Induction Generator in Direct Grid Connected Condition with Maximum Power point tracking of Wind Turbine

In this research a new control system for MPPT in a grid connected three-phase squirrel cage induction wind turbo-generator is presented. This generator is consisted of two Isolated three-phase windings. The first windin...

Analysis of Bifurcation Phenomenon in a Grid-Connected Electric Arc Furnace

This paper aims to study the stability and dynamic behavior of a grid-connected electric arc furnace system, using bifurcation theory. This theory introduces a systematic method for stability analysis of dynamic systems,...

Design and Implementation of a High Step-Up Boost-Sepic Hybrid Converter with Soft Switching

In this paper a compound boost- sepic converter with soft switching for high voltage application is proposed. One of the advantages of this converter is that, the main switch is turned on under the ZCS condition without...

Design and Implementation of Half-Bridge LLC Resonant Converter by FHA Technique

Although in existence for many years, only recently has the LLC resonant converters, in particular in its half-bridge implementation, gained in the popularity it certainly deserve. The advantages such as high efficiency,...

Download PDF file
  • EP ID EP317665
  • DOI -
  • Views 124
  • Downloads 0

How To Cite

Farzad Hajimohammadi, Bahador Fani (2017). Adaptive Coordination of Fuse – Recloser in a Distribution System with High PV Penetration. روش های هوشمند در صنعت برق, 8(30), 23-32. https://europub.co.uk/articles/-A-317665