Advantages of Using FACTS Controller in AC - HVDC Transmission Lines

Abstract

The search for enhanced controllability of power on ac transmission networks was initiated by newly acquired current and power controllability in HVDC transmission. Replacement of mercury-arc valves by thyristors yielded robust ac / dc converters, minimized conversion losses, and yielded fast control on transmitted power so much so that line-to-ground fault clearing became possible without the use of circuit breakers. Instead, by rapidly attaining current zero through the use of current controllers and, in addition, by rapidly recovering the electromagnetic energy stored in the energized line, the faulted dc line could be isolated by low interruption rating isolators. The very fast power controllability in HVDC systems made them candidates for special applications in back-to-back configurations to control the power exchange between the networks they linked. The rapid control of power led to the added use of HVDC links for enhancing transient stability of connected systems through active-power damping. The enhancement in stability was accomplished by adding auxiliary signals in the current controllers of the converters.

Authors and Affiliations

Alok Kumar

Keywords

Related Articles

Design and Analysis of AODV Routing Protocol in VANET Using NS-2

In last three decade ,tremendous improvement is made in research area of wireless adhoc network and now a days ,one of the most attractive research topic is inter vehicle communication i.e. realization of mobile adhoc n...

Improvement of Power Quality using Shunt Active Power Filter by Neural Learning Algorithm Technique

This paper presents a better analysis of Shunt active power filter for enhancing the power quality. The shunt active power filter has been designed to mitigate total harmonics distortions, instantaneous power factor and...

Image Generation in Microprocessor-based System with Simultaneous Video Memory Read/Write Access

In this paper we present a new architecture of video memory data handling in microprocessor-based systems. This architecture is a solution for the real time image processing systems which requires a significant recordin...

IGBT based Multiport Bidirectional DC-DC Converter with Renewable Energy Source

Future renewable energy systems will need to interface with several energy sources such as fuel cells and photovoltaic array with battery backup. For standalone systems, backup storage is required for dynamic response....

Time Series Analysis of Glacial Lake in Western Himalayas Based on NDWI and MNDWI

This Water always appears diversely, which makes its extraction not so simple. In this paper, we propose a new, simple, fast and accurate methodology based on a combination of the two indices NDWI and MNDWI for calculat...

Download PDF file
  • EP ID EP19203
  • DOI -
  • Views 253
  • Downloads 10

How To Cite

Alok Kumar (2014). Advantages of Using FACTS Controller in AC - HVDC Transmission Lines. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 2(12), -. https://europub.co.uk/articles/-A-19203