Agreement of Axial Length Measurements by Three Different Biometric Devices
Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 6
Abstract
ABSTRACT Introduction: Accurate Intraocular Lens (IOL) power calculation is crucial for spectacle independence and patient satisfaction post cataract surgery. Of the various parameters measured to calculate IOL power, Axial Length (AL) is the most crucial. There have been several advances in AL measurement devices with the current gold standard being Optical Biometry (OB). However, OB cannot be used in all cases and hence the earlier Ultrasound (US) biometry continues to be relevant. It is however important to conduct agreement analysis with the gold standard to ensure accuracy of results in all cases. Aim: To compare the AL measurements obtained by Tomey AL 4000 US biometer and pachymeter (Tomey US), built in US biometer of the Nidek AL Scan biometer (Nidek AL US), and the Nidek AL partial coherence interferometry optical biometer (Nidek AL OB). Materials and Methods: This was a non-interventional cross-sectional observational study. Patients with immature cataract satisfying the inclusion criteria scheduled for surgery and undergoing biometry underwent AL measurements by the three methods. AL measurements obtained with the two US devices were compared with OB measurements and agreement analysis was done. Results: A total of 98 eyes of 60 patients were studied. The average AL measured by the three devices were, 22.97±0.79 mm by Tomey US, 23.24±0.89 mm by the built in applanation US of Nidek AL US scan and 23.08±0.81 mm by the Nidek AL OB. The mean inter-device difference in AL between Tomey US and Nidek AL OB was -0.11±0.15 mm and 0.16±0.44 mm between Nidek US and Nidek OB. There was excellent correlation between the Nidek AL OB and the Tomey US, Interclass Correlation was (ICC)=0.98, 95% CI (0.95, 0.99). Bland Altman Plot analysis also showed high agreement between these two devices. About 94% of the values were within 0.3 mm difference between these two devices and there were no eyes with ≥1 mm difference. Conclusion: There was excellent correlation of AL as measured by Nidek AL OB and Tomey US.
Authors and Affiliations
Anika Amritanand, Arathi Ro ddam Simha, Ringsar Baglari, Jenifer Roselin, John Michael, Gowri Mahasampath
Gitelman Syndrome in a Case of Diabetic Kidney Disease: A Diagnostic and Therapeutic Dilemma
ABSTRACT Gitelman syndrome is an autosomal recessive disorder that usually presents with hypokalemia, hypomagnesemia, hypocalciuria and normal blood pressure. In contrast to Bartter syndrome it presents in late adulthood...
Journey from Fighters to Survivors: Quality of Life and Mental Status in Cancer Patients in a Rural Tertiary Care Hospital
ABSTRACT Introduction: Cancer is a major public health burden in India. Though modern medicine has made tremendous advancements in the treatment of cancers, still morbidity and mortality remain high. It affects different...
Significance of Serum Vitamin D Level in Tuberculosis Patients
Introduction: The role of vitamin D in bone homeostasis is well known but nowadays, its role in various essential body processes including prevention of various infective and chronic illnesses like Tuberculosis (TB), by...
Bilateral Psammomatoid Ossifying Fibroma of Maxilla
ABSTRACT Ossifying-Fibroma (OF) is a benign neoplasm histopathologically composed of fibrocellularstroma and variable amount of mineralized material. Generally, these tumours in jaw bones are found as solitary lesions. O...
Melena Secondary to Duodenal Dieulafoy’s Lesion: A Rare Case Report
Melena is one of the presenting feature of Upper Gastrointestinal Bleeding (UGIB). Melena due to Dieulafoy’s lesion in the duodenum is one of the obscure causes of Gastrointestinal Bleeding (GIB) and is a rare but life t...