Agreement of Axial Length Measurements by Three Different Biometric Devices

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 6

Abstract

ABSTRACT Introduction: Accurate Intraocular Lens (IOL) power calculation is crucial for spectacle independence and patient satisfaction post cataract surgery. Of the various parameters measured to calculate IOL power, Axial Length (AL) is the most crucial. There have been several advances in AL measurement devices with the current gold standard being Optical Biometry (OB). However, OB cannot be used in all cases and hence the earlier Ultrasound (US) biometry continues to be relevant. It is however important to conduct agreement analysis with the gold standard to ensure accuracy of results in all cases. Aim: To compare the AL measurements obtained by Tomey AL 4000 US biometer and pachymeter (Tomey US), built in US biometer of the Nidek AL Scan biometer (Nidek AL US), and the Nidek AL partial coherence interferometry optical biometer (Nidek AL OB). Materials and Methods: This was a non-interventional cross-sectional observational study. Patients with immature cataract satisfying the inclusion criteria scheduled for surgery and undergoing biometry underwent AL measurements by the three methods. AL measurements obtained with the two US devices were compared with OB measurements and agreement analysis was done. Results: A total of 98 eyes of 60 patients were studied. The average AL measured by the three devices were, 22.97±0.79 mm by Tomey US, 23.24±0.89 mm by the built in applanation US of Nidek AL US scan and 23.08±0.81 mm by the Nidek AL OB. The mean inter-device difference in AL between Tomey US and Nidek AL OB was -0.11±0.15 mm and 0.16±0.44 mm between Nidek US and Nidek OB. There was excellent correlation between the Nidek AL OB and the Tomey US, Interclass Correlation was (ICC)=0.98, 95% CI (0.95, 0.99). Bland Altman Plot analysis also showed high agreement between these two devices. About 94% of the values were within 0.3 mm difference between these two devices and there were no eyes with ≥1 mm difference. Conclusion: There was excellent correlation of AL as measured by Nidek AL OB and Tomey US.

Authors and Affiliations

Anika Amritanand, Arathi Ro ddam Simha, Ringsar Baglari, Jenifer Roselin, John Michael, Gowri Mahasampath

Keywords

Related Articles

Effects of Tamoxifen-Loaded Solid Lipid Nanoparticles on Kidney and Liver of Female Ovariectomized Rats

Introduction: Tamoxifen (TMX) has harmful dose-dependent long-term side effects such as liquid retention in postmenopausal breast cancer patients. Although, encapsulation of low-dose TMX in colloidal delivery systems hav...

Teneligliptin in Management of Diabetic Kidney Disease: A Review of Place in Therapy

ABSTRACT Diabetes is a global health emergency of this century. Diabetic nephropathy is the most common microvascular complication associated with Type 2 Diabetes Mellitus (T2DM). T2DM has been reported as a major etiolo...

Occlusal Traits of Primary Dentition among Pre-School Children of Mehsana District, North Gujarat, India

Introduction: Aesthetic and functional problems in the dentofacial complex among children are often attributed to the disturbances in the dentofacial growth and development. This can be recognized during routine dental v...

Factors Affecting the Prognosis and Overall Survival in Patients with Uterine Papillary Serous Carcinoma

ABSTRACT Introduction: Uterine Papillary Serous Carcinoma (UPSC) is a prototype of Type II Endometrial Cancers (EC) and represents 5-10% of all EC. It is clinically aggressive and responsible for over 50% of relapses and...

Oral Spindle Cell Sarcoma: A Rare Case Report and Review of Literature

Spindle cell lesions of the head and neck region are diverse in nature by means of clinical and biological heterogeneity. Though few lesions are found to be malignant, several others are benign or merely reactive in natu...

Download PDF file
  • EP ID EP524005
  • DOI 10.7860/JCDR/2018/31225.11592
  • Views 85
  • Downloads 0

How To Cite

Anika Amritanand, Arathi Ro ddam Simha, Ringsar Baglari, Jenifer Roselin, John Michael, Gowri Mahasampath (2018). Agreement of Axial Length Measurements by Three Different Biometric Devices. Journal of Clinical and Diagnostic Research, 12(6), 1-4. https://europub.co.uk/articles/-A-524005