Agreement of Axial Length Measurements by Three Different Biometric Devices

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 6

Abstract

ABSTRACT Introduction: Accurate Intraocular Lens (IOL) power calculation is crucial for spectacle independence and patient satisfaction post cataract surgery. Of the various parameters measured to calculate IOL power, Axial Length (AL) is the most crucial. There have been several advances in AL measurement devices with the current gold standard being Optical Biometry (OB). However, OB cannot be used in all cases and hence the earlier Ultrasound (US) biometry continues to be relevant. It is however important to conduct agreement analysis with the gold standard to ensure accuracy of results in all cases. Aim: To compare the AL measurements obtained by Tomey AL 4000 US biometer and pachymeter (Tomey US), built in US biometer of the Nidek AL Scan biometer (Nidek AL US), and the Nidek AL partial coherence interferometry optical biometer (Nidek AL OB). Materials and Methods: This was a non-interventional cross-sectional observational study. Patients with immature cataract satisfying the inclusion criteria scheduled for surgery and undergoing biometry underwent AL measurements by the three methods. AL measurements obtained with the two US devices were compared with OB measurements and agreement analysis was done. Results: A total of 98 eyes of 60 patients were studied. The average AL measured by the three devices were, 22.97±0.79 mm by Tomey US, 23.24±0.89 mm by the built in applanation US of Nidek AL US scan and 23.08±0.81 mm by the Nidek AL OB. The mean inter-device difference in AL between Tomey US and Nidek AL OB was -0.11±0.15 mm and 0.16±0.44 mm between Nidek US and Nidek OB. There was excellent correlation between the Nidek AL OB and the Tomey US, Interclass Correlation was (ICC)=0.98, 95% CI (0.95, 0.99). Bland Altman Plot analysis also showed high agreement between these two devices. About 94% of the values were within 0.3 mm difference between these two devices and there were no eyes with ≥1 mm difference. Conclusion: There was excellent correlation of AL as measured by Nidek AL OB and Tomey US.

Authors and Affiliations

Anika Amritanand, Arathi Ro ddam Simha, Ringsar Baglari, Jenifer Roselin, John Michael, Gowri Mahasampath

Keywords

Related Articles

Radiological Biometric Study of Metatarsals and Phalanges

Introduction: Several diseases affect the forefoot bones. Relative dimensions of the forefoot bones are important considerations for preoperative and postoperative assessment of surgeries. The choice of a particular surg...

Uterine Gangrene and Mechanical Intestinal Obstruction in a Teenager Following Unsafe Abortion

ABSTRACT Unsafe abortion often leads to complications since it is carried out by untrained persons in an unsafe environment. The most common complications are anaemia, bowel injury, bladder injury, uterine perforation, a...

Changes in Posterior Segment Optical Coherence Tomography after Intravitreal Triamcinolone Acetonide Injection

ABSTRACT Introduction: Triamcinolone acetonide is a potent synthetic corticosteroid. It is a long acting depot preparation of triamcinolone having solely glucocorticoid activity. As a part of glucocorticoid activity, it...

Clinical Tools and Biochemical Markers to Assess Short-Term Mortality in Acute Exacerbation of Chronic Obstructive Pulmonary Disease (COPD)

Introduction: Acute exacerbation of COPD is one of the leading causes of death worldwide. Aim: This study was aimed to study the role of clinical tools and biochemical markers which have significant impact on short-term...

Enclosed by Others: Post Haematopoietic Stem Cell Transplantation Patients Experience-A Phenomenological Study

ABSTRACT Introduction: Haematopoietic Stem Cell Transplantation (HSCT) has been considered as final treatment strategy for many diseases. Many quantitative studies have been conducted regarding the difficulties that thes...

Download PDF file
  • EP ID EP524005
  • DOI 10.7860/JCDR/2018/31225.11592
  • Views 62
  • Downloads 0

How To Cite

Anika Amritanand, Arathi Ro ddam Simha, Ringsar Baglari, Jenifer Roselin, John Michael, Gowri Mahasampath (2018). Agreement of Axial Length Measurements by Three Different Biometric Devices. Journal of Clinical and Diagnostic Research, 12(6), 1-4. https://europub.co.uk/articles/-A-524005