An Analysis of the Destructive Influence of Water Saturation on the Durability of Concrete Exposed to a Fire

Journal Title: Safety & Fire Technology - Year 2016, Vol 41, Issue 41

Abstract

Aim: The purpose of this paper is to present the results of a study involving concrete, containing sanitary ceramic waste as an aggregate, in context of resistance properties to high temperatures. Standardized concrete specimens were subjected to initial saturation with water and subsequently exposed to a heating process according to a predefined “temperature-time” schedule. Based on the previous experiments, the authors obtained a concrete with increased resistance to the effect of fire and, simultaneously, resistant to effects of thermal spalling. Methods: Concrete specimens used for strength studies were developed using alumina cement mixed with sanitary ceramics waste aggregate. The first batch of specimens were saturated by complete submersion in water for a period of 5 minutes. Subsequently, the removed specimens were dried for 10 minutes. A second batch of specimens was fully submerged for 12 hours, and similarly to the first batch, the specimens were dried. Next, the prepared specimens were placed in a PK 1100/1 type medium range temperature furnace. The heating process was initiated at a predefined “temperature-time” schedule, until a temperature of 1000°C was achieved. Durability tests were performed 30 days after heating. Results: The derived test results verified the significant impact of moist conditions, in which concrete specimens were placed and secondly, the high temperature impact on the specimen durability. A porous concrete prepared based on the design experiences of refractory concrete after heating, which simulated fire conditions, was characterised by a compressive strength of 27 MPa. For the same concrete after submersion in water for 5 minutes and heating, the average strength value was 6.42 MPa. While for the concrete saturated for 12 hours the obtained compressive strength value was 5.79 MPa. Although specimens were subjected to the same manufacturing treatments and care, they absorbed different amounts of water. This was revealed by weighing and is attributable to their non-standard porous structure and significantly high absorption level of ceramic aggregate. The specimens were heated to 1000°C and no thermal spalling was observed for all tested specimens. Conclusions: Study results reveal the destructive impact that moisture can have on concrete, when exposed to the influence of fire. The cause of such a development is perceived to stem from the disturbance caused to the composite structure by the ingress of water, which increases in volume during the heating process. From a performed experiment it is evident that there is a need to conduct an evaluation of durability for all concrete elements, which are exposed to the influence of fire. Such elements, despite constancy associated with their external features, apparent invariable structure and form, in fact can have significantly lower durability parameters, which can only be revealed during laboratory tests.

Authors and Affiliations

dr inż. Bartosz Zegardło, st. kpt. dr inż. Paweł Ogrodnik

Keywords

Related Articles

The Dependence of Water Distribution on the Flow Coefficient of Selected ESFR Sprinklers

Aim: The purpose of this paper is to present the results from experiments involving the distribution of water from selected quick-response sprinklers with a diameter of 20 mm, known as Early-Suppression Fast-Response (ES...

Zygmunt Jarosz – pionier pożarnictwa polskiego

Czytelnikom czasopisma „BiTP. Bezpieczeństwo i Technika Pożarnicza” w rozdziale „Postacie Pożarnictwa” od 2015 roku przedstawiane są biografie wybranych postaci zasłużonych dla polskiego pożarnictwa. W bieżącym numerze p...

The Impact of the Fire Source Location on Fire Development in a Large-Space Steel Commercial Building

Aim: The aim of this paper is to show that fire development in a large-space steel commercial building may have a different intensity depending on the location in which the fire originated. Buildings of this type are u...

Model matematyczny zmian stężenia wodoru w atmosferze. Rzeczywista sytuacja obliczeniowa dla obiektu z systemem wentylacji

ABSTRAKT Cel: Celem artykułu jest analiza zmian stężenia wodoru w atmosferze w dużych pomieszczeniach lub obiektach, w których przewiduje się ciągłą niewielką emisję tego gazu. Analizę przeprowadzono w odniesieniu do obi...

An Analysis of the Location of Emergency Exits as a Factor Impacting on Human Safety under Fire Conditions in Road Tunnels with the Longitudinal Ventilation System

Objective: This study examines the results of studies of selected worldwide legal acts stipulating the distances between escape routes in road tunnels, as well as the results of the verification of selected legal restric...

Download PDF file
  • EP ID EP90845
  • DOI 10.12845/bitp.41.1.2016.3
  • Views 139
  • Downloads 0

How To Cite

dr inż. Bartosz Zegardło, st. kpt. dr inż. Paweł Ogrodnik (2016). An Analysis of the Destructive Influence of Water Saturation on the Durability of Concrete Exposed to a Fire. Safety & Fire Technology, 41(41), 27-35. https://europub.co.uk/articles/-A-90845